17. In the Foreground Color field, specify the value of the foreground color.
For example, #999999.
18. In the Separator Color field, specify the value of the separator color
.
For example, #46008F.
19. In the Max Bandwidth Down field, specify the maximum rate at which a client can receive
data from the network.
The rate is in bytes per seconds. 0 indicates the limit is not enforced. The range is 0 to
53687091
1.
20. In the Max Bandwidth Up field, specify the maximum rate in bytes per second at which a
client can send data into the network.
A value of 0 indicates the limit is not enforced. The range is 0 to 536870911.
21. In the Max Input field, specify the maximum number of octets that the user is allowed to
transmit.
After this limit is reached, the user is disconnected. 0 indicates that the limit is not
enforced.
The range is 0 to 4294967295.
22. In the Max Output field, specify the maximum number of octets that the user is allowed to
receive.
After this limit is reached, the user is disconnected. 0 indicates the limit is not enforced.
The range is 0 to 4294967295.
23. In the Max T
otal field, specify the maximum number of octets that the user is allowed to
transfer, meaning the sum of octets transmitted and received.
After this limit is reached, the user is disconnected. 0 indicates the limit is not enforced.
The range is 0 to 4294967295.
24. Click the Add button.
The captive portal instance is added.
Configure Captive Portals Bindings
You can associate a configured captive portal with a specific network (SSID). The CP feature
runs only on the interfaces you specify. Multiple interfaces can be associated with a CP, but
an interface can be associated to only one CP at a time.
To configure captive portal bindings:
1. Launch a web browser
.
2. In the address field of your web browser
, enter the IP address of the switch.
The login window opens.
3. Enter admin as the user name, enter your local device password,
and click the Login
button.