User Manual

13
3.4 LED and button functions
LED indicators
RJ45 green
Network Link (lit) + Activity (flashes)
RJ45 yellow
1x flash when the device starts
3x flash when the internal system restarts
Flashing (2 sec lit, 1 sec dark) when the Eth cable is disconnected
and the device is running (connected to power).
M2M (red) only PowerPDU 8QS
Blink when some M2M communication is in progress.
Blink when NETIO Cloud communication is in progress.
Device Web administration / Mobile app is not indicated.
SETUP button
Switching all outputs
Output test:
Press the SETUP button 3x rapidly.
If any of output is On (1) -> Off (0).
If all outputs are Off (0), All outputs -> On (1).
Restoring factory defaults
Disconnect the device from the power. Press and hold the button.
Connect the device to the power grid (button is pushed) and wait at
least 10 seconds until the yellow LED on the RJ45 jack flashes 3 times,
release the button.
The device reverts to factory settings.
3.5 Minimum system requirements (for configuration)
A device with an Internet browser (Firefox, Chrome, Safari, Microsoft Internet Explorer, Opera, Mozilla
etc.) that has JavaScript and cookies enabled.