User Manual

48
When the Modbus/TCP is enabled, other M2M protocols are disabled except SNMP. After clicking
Save changes, the notification message about the deactivation of the other protocol appears.
Modbus/TCP function and registers overview
Function Register Value Description
0x01 102(101) 0/1 Read 1st output state (101 when Wire address used)
0x01 103 0/1 Read 2nd output state
0x01 104 0/1 Read 3rd output state
0x01 105 0/1 Read 4th output state
0x01 106 0/1 Read 5th output state
0x01 107 0/1 Read 6th output state
0x01 108 0/1 Read 7th output state
0x01 109 0/1 Read 8th output state
0x02 802 0/1 Read 1st input state
0x03 1 uInt16 Number of digital inputs
0x03 2 uInt16 Number of digital outputs
0x03 3 uInt16 Number of metered digital outputs
0x03 102 uInt16 1st output state
0x03 103 uInt16 2nd output state
0x03 104 uInt16 3rd output state
0x03 105 uInt16 4th output state
0x03 106 uInt16 5th output state
0x03 107 uInt16 6th output state
0x03 108 uInt16 7th output state
0x03 109 uInt16 8th output state
0x03 202 uInt16 "Short" delay of 1st output [s*10]
0x03 203 uInt16 "Short" delay of 2nd output [s*10]
0x03 204 uInt16 "Short" delay of 3rd output [s*10]
0x03 205 uInt16 "Short" delay of 4th output [s*10]
0x03 206 uInt16 "Short" delay of 5th output [s*10]
0x03 207 uInt16 "Short" delay of 6th output [s*10]
0x03 208 uInt16 "Short" delay of 7th output [s*10]
0x03 209 uInt16 "Short" delay of 8th output [s*10]
0x04 1 uInt16 Power grid frequency [Hz*100]
0x04 2 uInt16 Voltage [V*10] RMS
0x04 3 uInt16 OverAll TruePowerFactor * 1000
0x04 4 uInt16 All outputs current [mA] (double)
0x04 5 uInt16 All outputs power [W] (double)
0x04 6 Int16 All outputs Phase shift [° *100](double)
0x04 101 uInt16 All outputs current [mA]
0x04 102 uInt16 1st output current [mA]
0x04 201 uInt16 All outputs power [W]
0x04 202 uInt16 1st output power [W]
0x04 301 uInt16 All outputs energy counter - 2 upper bytes [Wh]
0x04 302 uInt16 All outputs energy counter - 2 lower bytes [Wh]
0x04 303 uInt16 1st output energy counter - 2 upper bytes [Wh]
0x04 304 uInt16 1st output energy counter - 2 lower bytes [Wh]