User's Manual

9
control code Sequence
number
identifier
Count NodeID RSSI
… NodeID RSSI
0x05 0x109F 0x5F
Byte 2byte Signed
(Clusterid0x FE60)
5-8. HeartBeat Technique
In a security system, it is important that Zone devices report the conditions to the central security unit (the
CIE device). To meet this need, Netvox came up with a technique called “HeartBeat”.
Right after Z308 enrolls to a security system, it sends a HeartBeat signal to the CIE device. Afterward, it will
send HeartBeat data every hour by default settings.
5-9. Battery
When the operating voltage is lower than 2.1V, the indicator will flash red once. Z308 will send a low-power
report to the ZigBee network.
The related data:
y Power configuration cluster (ID:0x0001)
y Battery voltage attribute (ID:0x0020)
5-10. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the Panic Button or 15 seconds.
Step2. Release the button after the indicator shows fast red flashes.
Step3. After 10 red flashes, it will go into turn-off mode. The indicator will be Off.
6. Home Automation Clusters for Z308
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by Z308.
1.End Point(s)0x01:
2.Device IDIAS Zone0x0402
3.EndPoint Cluster ID
Cluster ID for Z308
Server side Client side
EP 0x01 (Device ID: IAS Zone(0x0402) )