User manual

A
5. If you change:
from natural gas G20 20 mbar to liquid gas,
fully tighten the bypass screw in.
from liquid gas to natural gas G20 20 mbar,
undo the bypass screw approximately 1/4 of a
turn.
Warning! Make sure the flame does not
go out when you quickly turn the knob
from the maximum position to the
minimum position.
Electrical connection
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug (if applicable).
The appliance must not be connected with an
extension cable, an adapter or a multiple socket.
There is a risk of fire.
Do not let the power cable to heat up to a
temperature of more than 90° C. The cable should
be guided by means of clamps fixed to the side of
the cabinet, in order to avoid any contact with the
equipment beneath the cooktop.
Make sure that there is access to the mains plug
after the installation.
Electrical Requirements
Permanent electrical installation must agree with the
latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety the installation must be
done by a qualified electrician (e.g. your local Electricity
Board, or a contractor who is on the roll of the National
Inspection Council for Electrical Installation Contracting
[NICEIC]).
The manufacturer refuses to be held
responsible, if these safety measures
are not abided by.
Supply connections
This hob has to be connected to 220-240 V (~ 50/60
Hz ) electricity supply.
The hob has a terminal block which is marked as
follows:
L — Live terminal
N — Neutral terminal
or E — Earth terminal
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system can take
the appliance load (see the rating plate)
2. The supply system is equipped with an efficient
earth connection in compliance with the current
standards and regulations
3. The outlet or omnipolar switch used for connection
is easily accessible with the appliance installed.
The appliance is supplied with a 3 core flexible power
cable with a 3 amp plug. If it is necessary to change the
fuse, use a 3 amp ASTA-approved (BS 1362) fuse.
A B
C
D
E
A. Green and Yellow
B. 3 amp fuse
C. Brown
D. Cord clamp
E. Blue
The wires in the cord are coloured as follows:
Green and yellow - Earth
Blue - Neutral
Brown - Live
Warning! A cut off plug inserted into a
13 amp socket is a serious shock
hazard. Ensure that the cut off plug is
disposed of safely.
11