Setup

ASSEMBLY INSTRUCTION etherCON CAT 6
I
-3-
9
10
7
8
Insert Load Bar and load Wires into open end.
Slide Load Bar into position against Jacket.
Trim leads so Jacket is 8.64 mm / 0.34” from edge.
Inser Wires and Load Bar into Plug and push ful forward.
Terminate Plug with Hand Terminator MOLEX #62202-
0500 or any other suitable crimp tool.
In the case of using shielded cable crimp shield to
connector.
8.64 mm
[0.34”]
R
R
11
BDA 194 20.05.2010
I