Specifications

SIZE: 210 x 275 mm
N4003 说明书
材质:80G 书写纸
单色黑白印刷
LED Indicator
This parameter can access you to choose the LED indicator to be on when the
plug (light) is on / off, or LED indicator remains on / off all times.
Operation: quickly press 5 times to change this parameter .
--- Parameter=1, size=1byte, Default=0
Value=0 (default) LED is On when the switch(light) is On.
Value=1
--- LED is Off when switch(light) is On.
Value=2
--- LED is always Off.
Value=3
--- LED is always On.
Auto Turn-Off Timer
This parameter can access you to set a timer to make the switch turn off
corresponds to number of minutes.
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
--- Parameter=2, Size=4, Value: 0 – 65535 (minutes);
Value=0 (default) disable
Auto Turn-On Timer
This parameter can access you to set a timer to make the switch turn on
automatically after the switch turned off. The numberentered as value
corresponds to number of minutes.
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=3, Size=4, Value: 0 – 65535 (minutes);
Operation: quickly press 8 times to change this parameter .
This parameter can access you to set the switch to be on / off after power failure.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=4, Size=1, Value=0(default)
Value=0(default) memory state before power failure
Value=1
--- The switch is off regardless of the state prior to power failure.
Value=2
--- The switch is on regardless of the state prior to power failure.
This switch will be return to state prior to the power failure after power is restored.
(LED flashes 3 times when the configuration parameter changed.)
This parameter determines the minimum change in power wattage (W) that will
result in sending new power report to the main controller.
Parameter=5, size=1byte, value=5W (default)
value range: 5 - 50W
This parameter determines minimum time that has to elapse before sending
new power report to the main controller.
Parameter=6, size=4byte, value=5Minute (default)
value range: 1 - 65535Minute
This parameter determines the minimum change in Current (A)
that will result in sending new power report to the main controller.
Parameter=7, size=1byte, Value=1: 0.1Adefault
value range: (1~10) x0.1A
value=1
--- 0.1A
value=2
--- 0.2A
value=3
--- 0.3A
value=10
--- 1A
This parameter determines the minimum change in consumed energy that will
result in sending new energy report to the main controller.
Parameter= 8, size=1byte, Value=1: 0.01KWHdefault
value range: (1~100) x0.01KWH
Value=1
--- 0.01KWH
value=2
--- 0.02KWH
value=3
--- 0.03KWH
value=100
--- 1KWH
Parameter Settings
Locally Button Press function:
1: press 1x: turn output ON or OFF
2: quickly press 3x: inclusion or exclusion
3: quickly press 5x: change Parameter 1
4: quickly press 8x: change Parameter 4
5: quickly press 10x: Reset KWH
6: Factory reset: click Z-Wave button twice quickly, then hold it at least 10 seconds.
背面
2. Your device may need to be within 100 feet of the controller to be included. If so,
include the device to the network within 10 feet of the controller and relocate it to
the desired position in your home. Be sure to refresh the network if the device is
included in this manner.
1. Plug the device you want to control into the Z-Wave Smart plug controlled outlet.
NOTE: Plug directly into the outlet, do not use with extension cords.
Notes:
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications. All
non-battery operated nodes within the network will act as repeaters regardless of
vendor to increase the reliability of the network. This Device supports Lifeline
(association group 1) supporting 1 node for lifeline communication. Group 1 must
be assigned the Node ID of the primary controller where unsolicited notifications
will be sent. The Z-Wave controller should set this association automatically after
inclusion. Lifeline association only supports the “Device Reset Locally” function.
Z-Wave Network Configuration
正面
Z-Wave Outdoor Plug
Energy Monitor
8. Protection function
(When the protection function is triggered, it needs to be powered the device on
again for normal use.)
Voltage protection: when the voltage135V, the device will be forcibly shut down
Current protection, when the current16A, the device will be forcibly shut down
Power Wattage protection, when the power2000W, the device will be forcibly
shut down.
Features:
1. Z-Wave control on / off.
2. Z-Wave controlled AC outlet for standard incandescent lighting, CFL/LEDs, fans
or small appliances (1800W Resistive Max).
3. Grounded 3-wire power connection for safety.
5. Built-in Z-Wave Plus signal repeater to extend network range.
6. S2 security and for reliable wireless communication.
7. Work with all certificated Z-Wave controllers.
4. Remembers and restores on / off status after power failure.
Z-WAVE INTEROPERABILITY
Adding Device To Z-Wave Network
(LED flashes 3 times when the configuration parameter changed.)
Energy(KWH) Report
Current(A) Report
Reports sending settings
Restores state after power failure
Power Wattage(W) Report
Time Report
Value=0 (default) disable
automatically after the switch turned on. The numberentered as value
Generic Device Class:
Specific Device Class:
Command Classes:
0x10 - GENERIC_TYPEGENERIC_TYPE_SWITCH_BINARY
0x00-SPECIFIC_TYPE_NOT_USED
0x5E-COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
0x25-COMMAND_CLASS_SWITCH_BINARY_V2,
0x70-COMMAND_CLASS_CONFIGURATION_V4,
0x85-COMMAND_CLASS_ASSOCIATION_V3,
0x8E-COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4,
0x59-COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
0x71-COMMAND_CLASS_NOTIFICATION_V8,
0x32-COMMAND_CLASS_METER_V5,
0x55-COMMAND_CLASS_TRANSPORT_SERVICE_V2,
0x86-COMMAND_CLASS_VERSION_V2,
0x72-COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2,
0x5A-COMMAND_CLASS_DEVICE_RESET_LOCALLY,
0x87-COMMAND_CLASS_INDICATOR_V3,
0x73-COMMAND_CLASS_POWERLEVEL,
0x9F-COMMAND_CLASS_SECURITY_2,
0x6C-COMMAND_CLASS_SUPERVISION,
0x7A-COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Adding Device To Z-Wave Network for QR CODE
Scan here for SmartStar inclusion
Note: DSK Code can be found on the
packaging box.
Do not remove or damage them.
Program button:
Press 1x: Manually
Press 3x: Z-Wave Network configuration
Press 10x: Reset KWH
LED indicator:
Blue: Light status indicator
Blue: ADD / Inclusion
Red: Network Failure / Over-temperature Warning
Purple: Remove / Exclusion
Power: 125VAC, 60Hz
Loading: 15A Max Resistive
Frequency: 908.42MHz
Temperature Range: 32° F ~104° F
Indoor use in dry location
Specification
Please contact us if you have any questions:
ask@minoston.com
www.minoston.com
1. Follow the instructions for your Z-Wave certified controller to remove a device
from the Z-Wave network.
2. Once the controller is ready to remove your device, press the manual/program
button on the smart plug 3 times quickly.
Again: If you have issues with pairing / including, please move the device as close
as possible to the hub and try again--you can move to your final location when
completed.
Note: If the manual button doesn't light up after pressed 3 times, please reset the
Device: click the button twice quickly then hold for at least 10 seconds.
This operation could be done when manual control is functional--single press can
turn on / off the lamp.
1. Follow the instructions for your Z-Wave certified controller to add a device to
the Z-Wave network.
2. Once the controller is ready to add your device, press the Manual/ Program
button on the smart plug 3 times quickly. The blue LED will blink quickly.
Auto-add mode: LED will blink within 30 seconds after first plugged in. Now, you
have completed control to turn your fixture ON/OFF according to groups, schedu-
les and interactive automation programmed by your controller.
If your Z-Wave certified controller features remote access, you can control your
fixture from your mobile devices.
Group 1 supports 1 node ID,Group 2 Supports maximum of 5 node ID’s
Association Group 1: Z-Wave Plus Lifeline
Association Group 2: Send Basic Set ON / Off
If you'd like to reset the KWH record, just click the button 10 times very quickly.
Network exclusion or factory reset will NOT automatically erase the KWH data.
Manual: Click the button twice quickly then hold for at least 10 seconds.
(Light flashes once when reset successfully.)
Host reset: Remove it from hub the device will be restore to factory default.
Our Products warrant this product to be free from manufacturing defects for a
period of one year from the original date of consumer purchase. This warranty is
limited to the repair or replacement of this product only and does not extend to
consequential or incidental damage to other products that may be used with this
product. This warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts or permit the
exclusion or limitation of incidental or consequential damage, so the above
limitations may not apply to you. This warranty gives you specific rights, and you
may also have other rights which vary from state to state.
Warranty
KWH Reset:
To Return The Device To Factory Defaults:
To Remove The Device:
Association Group:
This device complies with part 15 of the FCC and Industry Canada license-exempt RSS
standard(s). Operation is subjected to the following two conditions:
FCC / IC
(1) This device may not cause harmful interference, (2) This device must accept any
interference received, including interference that may cause undesired operation.
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the
— Consult the dealer or an experienced radio / TV technician for help.
receiver is connected.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
occur in a particular installation. If this equipment does cause harmful interference to
Important note:
To comply with the FCC RF exposure compliance requirements,
no change to the antenna or the device is permitted. Any change to the antenna or the
device could result in the device exceeding the RF exposure requirements and void
user’s authority to operate the device.
CAUTION - PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and
local regulations in the United States, or the Canadian Electrical Code and local regulati-
ons in Canada If you are unsure or uncomfortable about performing this installation co-
nsult a qualified electrician.
WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS
MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment.
Z-Wave devices should never be used to control the On / Off status of Medical and / or
Life Support equipment.
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUN-
DING TYPE PLUG THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG WILL
ONLY FIT INTO A GROUNDING TYPE POWER OUTLET. IF THE PLUG DOES
NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO
INSTALL THE PROPER
OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF
OVERHEATING AND POSSIBLE DAMAGE TO
OTHER EQUIPMENT
• DO NOT EXCEED RATINGS
• DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control appliances.
Reason being is because the appliance you want to control may be in a separate room
and if unintentional behavior occurs (such as adevice turning on or off - either intention-
ally via schedules, or unintentionally via network error) this event may lead to a hazard-
ous condition. For these reasons, please note the following suggestions:
1) Do not include Z-Wave devices in Groups or Scenes if they control appliances.
2) Do not use Z-Wave devices to control electric heaters or any other appliances
which may present a hazardous condition due to unattended, unintentional, or automa-
tic power control.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications could void
the user’s authority to operate the equipment.
N4003
100 feet