Install Instructions
6
E. Install Drain Valve in Tapping 'F'. See Figure 4.
Figure 5: Assembly Diagram for McDonnell & Miller 67 Low Water Cutoff
Figure 4: Purpose of Tappings
Table 3: Purpose of Tappings
F. Connect system supply and return piping to boiler.
See Figure 6. Also consult Residential Hydronic
Heating Installation and Design I=B=R Guide.
Maintain minimum ½ inch clearance from hot water
piping to combustible materials.
WARNING
Safety valve discharge piping must be piped near
oor to eliminate potential of severe burns. Do
not pipe in any area where freezing could occur.
Do not install any shut-off valves.
Tapping Size Purpose
A 2"
30 - 70: Plugged, Optional Second Supply
80: Second Supply
B ¾" Pressure Gauge (bushed to ¼)
C ½" Gauge Glass / Float LWCO
D 2" Return (Standard)
E ¾" Safety Valve
F 2" Drain Valve Return (Alternate)
G 2" Supply
H ¾" Limit
K ¾"
Probe Low Water Cutoff
(Plugged with McDonnell & Miller 67 LWCO)
III. Steam Piping and Trim (continued)