Product Overview
©2012 New Yorker Boiler Company, Inc., Hatfield, PA
(215) 855-8055
www.newyorkerboiler.com
PL81420101003-9/12-5Ms
Ratings&Specifications
Model
Input
Gas
(MBH)
DOE
Heating
Capacity
(MBH)
AHRI
Net
Steam
(MBH)
AHRI
Net
Steam
(sq.ft.)
AFUE%
Electronic
Ignition
CGS30A 70 57 43 179 81.4
CGS40A 105 86 65 271 81.4
CGS50A 140 115 86 358 81.4
CGS60A 175 143 107 446 81.4
CGS70A 210 172 129 538 81.5
CGS80A 245 210 151 629 81.5
Model
Dimensions(inches)
Chimney
Req.
Approx.
ShipWt.
(lbs.)A B C D
E
(nat.gas)
E
(LP)
F
(nat.gas)
F
(LP)
CGS30A 12-3/16 4-1/2 4 6-1/8 53-1/8 53-1/8 9-3/4 9-3/4 8”x 8”x 15’ 305
CGS40A 15-3/4 4-1/2 5 7-1/8 50-1/4 50-1/4 6 6 8”x 8”x 15’ 307
CGS50A 19-3/8 4-1/2 6 9-3/4 52-1/8 55-1/8 7-1/4 10-1/4 8 x 8”x 15’ 440
CGS60A 22-7/8 4-1/2 6 11-1/2 53-3/8 56-3/8 8-1/2 11-1/2 8 x 8”x 15’ 502
CGS70A 26-1/2 5-1/4 7 13-1/4 55-7/8 58-7/8 9-3/4 12-3/4 8”x 8 x 15’ 566
CGS80A 30 5-1/4 7 15 57-1/8 60-3/4 11 14-1/2 8”x 8 x 15’ 650
Standard Features
• Fullypackaged
• Drafthood
• Largesteamdisengagingarea
• Flameroll-outswitch
• Pressuregauge
• Safetyreliefvalve(15PSI)
• Steamsyphon
• Honeywellelectronicignition
• Probe-typeLWCO
• Blockedventswitch
• Ventdamper
• Drainvalve
• HoneywellPressuretrol
• 2”supplyconnection
• 2”returnconnection
A
S
M
E
H
MADE IN
U.S.A.
Designworkingpressure:15PSIG,steamonly