Installation Guide
56
Troubleshooting
PROBLEM POSSIBLE CAUSES
9. Grill and control panel lights
not working
Unit not connected to power.
Plug transformer cord into power box (from working GFI protected
outlet).
Faulty transformer.
Check transformer output – should be 12VAC. Replace if required.
Terminals on switch or circuit board are corroded or loose.
Clean connections and ensure connectors are pushed together rmly.
Access to circuit board is under electrical cover on left side of cabinet.
10. Burner goes out Location of grill
High wind and wind directly on the back of the grill can cause blow-
outs. Locate the grill towards the prevailing wind.
Check ame
Follow steps outlined in Step 8. of troubleshooting
Burners installed incorrectly
Correctly-installed burners should be seated rmly and level with no
side-to-side movement.
11. Burner goes out when set to
low
Supply hose is pinched.
Reposition supply hose as necessary.
Dirty or clogged orice. Spider webs or other matter in venturi
tube.
Clean burner orice . Clean out venturi tube.
12. Rotisserie won’t light No power to ignition
See Step 10.
Burner won’t light
Refer to steps outlined in Step 12 & 13. of troubleshooting
13. Rotisserie lights and goes
out immediately upon control
knob release.
Continue holding safety valve button in depressed position until
burner remains lit when released. Continue holding safety valve button
in depressed position until
burner remains lit when released.