PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner’s Manual
BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT, LEVEL SURFACE AT LEAST 14” (36CM) AWAY FROM ANY OTHER OBJECTS (FIG 1 & 4). FIG. 1 DO NOT PLACE OBJECTS ON THE UNIT AND DO NOT COVER OR OBSTRUCT THE INLET OR OUTLET GRILLES (FIG. 2).
FOR MAXIMUM EFFICENCY: Make sure doors and windows are closed while the portable air conditioner is in use. Also keep curtains and blinds closed during the sunniest parts of the day while it is in operation. Frequently clean the filters. Once the room or area has reached your desired comfort level, be sure to reduce the unit’s temperature and ventilation settings.
PARTS LIST Front Back FIG.5 1. 2. 3. 4. 5. 6. Display window Control panel Control buttons Louvers Carrying handle Casters 7. 8. 9. 10. 11. 12. FIG.6 Cord wrap Air filter Air inlet Exhaust air outlet Air inlet Water plug/drainage port Accessories 13. Hose adaptor (goes over hose and into the window kit) 14. Exhaust hose 15. Activated carbon filter 16. Extendable window kit 17. Hose for continuous drainage 18. Remote control FIG.
INSTALLATION INSTRUCTIONS Installing the Exhaust Hose FIG.8 1. Open the window and insert the window kit into the open gap. 2. Close the window until the window kit is held securely. size of the window kit and secure it with screws. You may need to adjust the This technique may also be used for sash windows. 3. Fit the exhaust hose into the exhaust air outlet located at the back of the air conditioner. 4. Attach the hose adapter onto the exhaust hose. 5. Attach the hose adapter to the window kit.
Positioning the Exhaust Hose Insert the exhaust hose into the back of the unit and tighten it into place. Avoid kinks and bends in the exhaust hose. FIG. 9 These can cause expelled moist air to accumulate, resulting in overheating and unexpected shut offs (See Fig 9 & 10). Τhe exhaust hose may be extended from 12 inches (300 mm) to 59 inches (1500 mm), FIG. 10 but for maximum cooling efficiency, use the shortest length possible. FIG.
Installing the Activated Carbon Filter 1. Remove the filter frame from the unit. 2. Remove the activated carbon filter from its plastic bag. 3. Insert the activated carbon filter into the back of the unit. 4. Reattach the filter frame onto the unit. FIG.
OPERATING INSTRUCTIONS Control Panel FIG.14 1. 2. 3. 4. 5. 6. 7. 8. 9. ON/OFF (power) button Timer button Timer indicator light Temperature increase button Compressor indicator light Full water tank indicator light Temperature decrease button Low ventilation indicator light High ventilation indicator light 10. 11. 12. 13. 14. 15. 16. 17.
Setting the Temperature 1. Press the UP or DOWN button to change the set temperature. 2. The display window will then indicate the set temperature. If no temperature is set, the display will show the room’s ambient temperature. 3. Please note that the default cooling temperature of this portable air conditioner is 75o F. Setting the Fan/Ventilation Speed 1. Press the SPEED button to select the desired fan speed (high or low). The appropriate indicator light (high or low) will turn on accordingly. 2.
Regulating the Air Flow Direction To control the air flow direction, adjust the knob on the louvers. FIG. 16 PLEASE NOTE: 1. To prolong the life of the compressor, after turning off the unit, please wait at least 3 minutes before turning it back on. 2. The cooling system will switch off if the ambient temperature is lower than the set temperature (the ventilation will keep working at the set level). If the ambient temperature rises above the selected level, cooling will resume.
DRAINING THE UNIT During the cooling process, some water will be extracted from the air and stored within the unit’s water reservoir. If the water reservoir is full, both the compressor and motor will stop and the unit will beep (press any button to stop the beeping sound). The full water tank indicator light will also start flashing. To resume cooling, empty the reservoir by following these steps: 1. Turn off the air conditioner and unplug it from the wall socket.
• The drainage hose may be extended by adding an extension hose using a suitable FIG.19 connector. Drainage hose included with the unit PLEASE NOTE: 1. The drain must be at or below the level of the drainage port. 2. The full water tank indicator light will not work when the unit is being continuously drained. 3. To extend the drainage hose, you can connect it with another hose with an overall diameter of 0.7” (18 mm). 4.
MAINTENANCE INSTRUCTIONS Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air conditioner, regularly clean the unit. Cleaning the Housing • Use a soft, damp cloth to wipe the body clean. • Never use strong chemicals, gasoline, detergents, chemically-treated cloths, or any other cleaning solutions to clean the air conditioner, as these can all potentially damage the unit’s housing.
TROUBLESHOOTING The air conditioner does not function. Is the air conditioner plugged in? Is the power outlet functioning correctly? Is the full water tank indicator light flashing? Is the ambient room temperature lower than the set temperature? The unit does not produce adequate cooling. Is the unit placed in direct sunlight? If so, close any curtains or move the unit to a more shaded area.
TECHNICAL SPECIFICATIONS Model Number: AC-10000E AC-10000H Voltage / Frequency 115V / 60Hz Power Consumption for cooling” 909W / 8.3A Power Consumption for heating” NIL 830W / 7.6A 300 m3/h Air Volume (Maximum Speed) Dehumidification Capacity 2.1 pints/hr (1 L/hr) Compressor Type Rotary Refrigerant Type R-410A Number of Fan Speeds 2 Timer 1 ~ 12 hours Exhaust Pipe Dimensions Ø4.72” X 59.06” (Ø120x1500 mm) Product Weight 50.7 lbs (23kg) Product Dimensions (W x D x H) 12.2” x 13.