k0045 PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC‐12000E, AC‐12000H Portable Air Conditioner Owner’s Manual
k0045 BEFORE USE GENERAL SAFETY INSTRUCTIONS: • ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT, LEVEL SURFACE AT LEAST 14 INCHES AWAY FROM ANY OTHER OBJECTS (Fig 1 & 4). • DO NOT PLACE OBJECTS ON THE UNIT, AND DO NOT COVER OR OBSTRUCT THE INLET OR OUTLET GRILLS (FIG. 2). • CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN THE UNIT IS IN USE.
k0045 PARTS LIST Front: 1. 2. 3. 4. Back: Control panel Louvers Carrying handle Casters 5. 6. 7. 8. 9. Accessories: 10. Exhaust hose 11. Hose adaptor (goes over the hose and into the window kit) 12. Extendable window kit 13. Activated carbon filter 14. Hose for continuous drainage 15.
k0045 INSTALLATION INSTRUCTIONS Installing the Exhaust Hose and Window Kit: Window Kit Wall or Window Adapter 14 " FIG.5 FIG.6 1. Open the window and insert the window kit into the open gap. 2. Close the window until the window kit is held securely. This technique may also be used for sash windows. 3. Fit the exhaust hose into the exhaust air outlet located on the back of the air conditioner. 4. Attach one end of the hose adapter onto the exhaust hose. 5.
k0045 Positioning the Exhaust Hose: • Insert the exhaust hose into the back of the unit and tighten it into place. • Avoid kinks and bends in the exhaust hose. This can cause moist air to accumulate, resulting in overheating and unexpected shut offs . • The exhaust hose may be extended from 12 inches (300 mm) to 59 inches (1500 mm), but for maximum cooling efficiency, use the shortest hose length possible. FIG.7 FIG.8 FIG.
k0045 Installing the Activated Carbon Filter: 1. Remove the filter frame from the unit. 2. Separate the filter from the filter frame. 3. Remove the activated carbon filter from its plastic bag. 4. Insert the activated carbon filter into the filter frame. 5. Reattach the filter onto the filter frame. 6. Insert the filter set into the unit. FIG.
k0045 OPERATING INSTRUCTIONS Control Panel 22 21 2 3 4 5 SPEED HEAT 6 7 MODE 8 AUTO COOL FAN 9 10 20 TIMER UP 19 SLEEP DOWN 11 ION ON/OFF 12 18 17 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. hi lo 1 COMP. 16 15 Fan speed (ventilation) button Timer button Display window Remote control receiver Heater indicator (for AC-12000H only ) Mode selection button Automatic mode indicator Cooling mode indicator Fan mode indicator Temperature increase button Temperature decrease button 14 12. 13. 14.
k0045 Setting the Mode/Function: 1. Press the MODE button to select the desired mode (cooling, fan or heating). Heating mode is only available on the AC-12000H. 2. The selected mode’s indicator light will turn on. Setting the Temperature: 1. Press the “Up” or “Down” button to change the set temperature. 2. The display window will indicate the set temperature. If no temperature is set, the display will show the ambient room temperature. 3.
k0045 Heating Mode: When the air conditioner is in heating mode, ambient warm air is recycled and used to heat your immediate area. The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed. When in heating mode, the machine can be set on HIGH or LOW speed. Ionizer: Press IONIZER button to activate the ionizer function. Error Messages: If there is an error with the air conditioner, the LCD screen will display “E1” or “E2.
k0045 DRAINING THE UNIT During the cooling process, some water will be extracted from the air and stored within the unit’s water reservoir. If the water reservoir is full, both the compressor and motor will stop and the unit will beep (press any button to stop the beeping sound). The full water tank indicator light will also start flashing. To resume cooling, empty the reservoir by following these steps: 1. Turn off the air conditioner and unplug it from the wall socket.
k0045 For Continuous Drainage: • • • Remove the rubber plug from the drainage port and retain it for future use. Connect the drain tube to the drainage port as shown (fig. 17). Connect the other end of the hose to a drain. Rubber plug Drain knob FIG.15 • The drain tube may be extended by adding an extension tube with a suitable connector. Drain tube FIG.16 Please Note: 1. The drain must be at or below the level of the drainage port. 2.
k0045 For Heating Mode: While using the heating function, please note the following: 1. In order to properly exhaust cool air, make sure the exhaust hose and window kit are properly installed (refer to page 6 for instructions). 2. Set up the air conditioner for continuous drainage using the drain tube (refer to page 13 for instructions). 3. The working range for the heating function is 32° F to 68°F. The unit may not provide optimal heating if used in temperatures outside this range. FIG.
k0045 MAINTENANCE INSTRUCTIONS Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air conditioner, regularly clean the unit. Cleaning the Housing: • Use a soft, damp cloth to wipe the body clean. • Never use harsh chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet.
k0045 TROUBLESHOOTING The air conditioner does not work. y y y y Is the air conditioner plugged in? Is the power outlet functioning correctly? Is the full water tank indicator light flashing? Is the ambient room temperature lower than the set temperature? The unit does not produce adequate cooling. y Is the unit placed in direct sunlight? If so, close any curtains or move the unit to a more shaded area.
k0045 TECHNICAL SPECIFICATIONS Model Number: AC-12000E AC-12000H 1166W / 11A 1166W/11A N/A 1054W/10.1A Air Volume (max. speed) 440m3/h 440m3/h Dehumidification Capacity 1.2L/hour 1.2L/hour Power Consumption for Cooling* Power Consumption for Heating * Voltage / Frequency 115V, 60Hz Compressor Type Rotary Refrigerant Type R-410A Number of Fan Speeds 2 Timer 1~24 hours Exhaust Pipe Dimensions Ø 5” X 59.06” Net Weight 63.9 lbs Dimensions 63.9 lbs 14.4"x 15.6" x 29.3" Notes: 1.