AC-14100E AC-14100H Portable Air Conditioner OWNER’S MANUAL Read and save these instructions. Manual v1.
A Name You Can Trust Trust should be earned and we will earn yours. Customer happiness is the focus of our business. From the factory to the warehouse, from the sales floor to your home, the whole NewAir family promises to provide you with innovative products, exceptional service, and support when you need it the most. Count on NewAir. As a proud NewAir owner, welcome to our family. There are no robots here, real people shipped your product and real people are here to help you.
READ AND SAVE THESE INSTRUCTIONS. TABLE OF CONTENTS Safety Information & Warnings ........................................................................... 4 Safe Operation Guidelines ........................................................................... 4 Energy SAving Tips ....................................................................................... 6 Disposal Guidelines ...................................................................................... 6 Parts List ................
COMPRESSOR TYPE: REFRIGERANT TYPE: NUMBER OF FAN SPEEDS: TIMER: EXHAUST PIPE DIMENSIONS: COOLING CAPACITY: EER: NOISE RATING: Rotary R-410A 3 1 – 24hours 5.59” x 59.06” (120 x 1500 mm) 14,000 BTUs 9.88 57 dB SAFETY INFORMATION & WARNINGS SAFE OPERATION GUIDELINES To reduce the risk of fire, electrical shock and/or injury to persons or property please follow basic safety precautions.
Contact a qualified person to carry out repairs. If the power cord is damaged it must be repaired by a qualified technician. Keep an air path of at least 14” (36 cm) all around the unit from walls, furniture and curtains. If the air conditioner is knocked over during use, turn off the unit and unplug it from the power supply immediately. o o o o Do not place objects on the unit, and do not cover or obstruct the inlet or outlet grilles.
• Keep the beverage cooler away from hazardous materials or combustible/flammable substances. • Use only genuine supplier’s replacement parts. Imitation parts can damage the unit, affect its operation or performance, and may void the warranty. ENERGY SAVING TIPS For maximum efficiency: • Use the air conditioner in the recommended room size (Up To 525 Square Feet). • Keep doors and windows closed while the portable air conditioner is in use.
PARTS LIST When you receive your unit, carefully remove the exterior and interior packaging. It is recommended that you retain the packaging for future use.
PARTS DIAGRAM 1. 2. 3. 4. Control panel Carrying handle Water tank Casters 5. 6. 7. 8. Air louvers Air filter Exhaust air outlet Air filter 9. 10. 11. 12. Air inlet Cord storage Air inlet Water plug/drainage hole ASSEMBLY & INSTALLATION INSTALLATION Before connecting the appliance to a power source, let it stand upright for approximately 2 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation. http://www.NewAir.
LOCATION This unit is a portable air conditioner that may be moved from room to room. Hot air must be exahusted out of the room for the appliance to work. This can be done with the included window kit or by cutting a hole into a wall. • • • • • The air conditioner should be placed on a firm foundation to minimize noise and vibration. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces.
1. 2. 3. 4. Cut a 6” (152 mm) diameter hole in the wall. Insert one end of the exhaust hose into the exhaust air outlet located on the back of the air conditioner. Insert the exhaust hose through the hole. On the other side of the wall, attach the round connector to the exhaust hose. When the air conditioner is not in use, cover the hole with the provided exhaust cap. http://www.NewAir.
POSITIONING THE EXHAUST HOSE • Slide the hose adaptor over the opening on the back of the unit. • Insert one end of the exhaust hose into the adapter. • Avoid kinks and bends in the exhaust hose. This can cause moist air to accumulate, resulting in overheating and unexpected shut offs. • The exhaust hose may be extended from 12” (300 mm) to 59” (1500 mm), but for maximum efficiency use the shortest hose length possible.
INSTALLING THE ACTIVATED CARBON FILTER 1. 2. Remove the filter from the unit. Separate the filter from the filter holder. 3. 4. 5. Remove the activated carbon filter from its plastic bag. Insert the activated carbon filter into the filter and attach holder. Reattach the filter holder onto the filter (make sure the active carbon filters will be held properly between the two pieces). Insert the filter set into the unit.
CONTROL PANEL DIAGRAM BUTTONS 1. ON/OFF (power) button 2. Mode button 3. Temperature increase button 4. Temperature decrease button 5. Fan speed (ventilation) button 6. Timer button 7. Sleep mode button CONTROL OPERATION LIGHTS AND INDICATORS a. Display b. Heater indicator (AC14100H only) c. Automatic mode indicator d. Cooling indicator e. Fan indicator f. High speed indicator g. Medium speed indicator h. Low speed indicator i. Receiver for remote control j. Timer indicator k. Sleep mode indicator l.
TURNING THE UNIT ON AND OFF 1. 2. 3. Press the ON/OFF button. The unit will work in cooling mode on low fan speed. The preset temperature is 75°F. At this time, the indicator lights will show any functions that are in progress. Please note the display window will show ambient room temperatures ranging from 32°F to 122°F. To turn the unit off, press the ON/OFF button again. SETTING THE FAN/VENTILATION SPEED Press the fan speed button to select the desired fan speed (high, medium, or low).
SETTING THE MODE/FUNCTION 1. 2. Press the MODE button to select the desired mode (cooling, heating and fan). Heating mode is only available on the AC-14100H. The selected mode’s indicator light will turn on. SETTING THE TEMPERATURE 1. 2. 3. Press the increase temperature or decrease temperature button to change the set temperature. The display window will then indicate the set temperature. If no temperature is set, the display will show the room’s ambient temperature.
All of the above functions can be controlled with the included remote. The remote requires 2 AAA batteries. ENERGY EFFICIENCY BOOSTING FUNCTION This unit is equipped with an energy efficiency boosting function. By adding water to the tank as shown below, energy efficiency can be increased, therefore saving you money on your energy bill and conserving the environment. The water helps to cool the compressor, cooling the exhaust and minimizing frost accumulation.
AUTOMATIC FUNCTIONS • • • The cooling system will turn off if the ambient temperature is lower than the set temperature. However the fan will continue operating at the set level. Once the ambient temperature rises above the set temperature, cooling will resume. The heating system will turn off if the ambient temperature is higher than the set temperature. However, the fan will continue operating at the set level. Once the ambient temperature drops below the set temperature, heating will resume.
4. 5. 6. 7. When the container is almost full, replace the water plug back into the drainage port and empty the water container. Repeat until the water reservoir is completely empty. Replace the water plug back into the drainage port and make sure it is firmly in place. Turn the unit back on. The warning signal should be off. CONTINUOUS DRAINAGE To operate the unit continuously without manually emptying the tank, follow these steps: 1. 2. 3.
• Set up the air conditioner for continuous drainage using the included drain tube. • The working range for the heating function is 45°F to 77°F. The unit may not provide optimal heating if used in temperatures outside this range. CLEANING & MAINTENANCE CLEANING YOUR PORTABLE AIR CONDITIONER Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air conditioner, regularly clean the unit.
END OF SEASON STORAGE 1. 2. 3. 4. 5. Completely drain any condensed water from the unit. Set the air conditioner on fan mode for a few hours to thoroughly dry the inside of the unit. Clean or change the filter. Unplug and store the power cord behind panel as shown. Place the unit back in its original carton and store it in a clean, dry area. TROUBLESHOOTING Problem Possible Causes Solution The air conditioner does not function. The unit may be plugged in using a different voltage.
Problem Possible Causes Solution There is an additional heat source in the room or there are too many people in the room. Lower the set temperature. The filter is dusty or dirty. Clean the filter per instructions above. Air inlet or air outlet is blocked. Make sure there are no obstructions to proper air circulation through the unit. The ambient room temperature is lower than the set temperature. Lower the set temperature. The unit is noisy. The unit is not leveled.
LIMITED MANUFACTURER’S WARRANTY This appliance is covered by a limited manufacturer’s warranty. For one year from the original date of purchase, the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship, provided the appliance has been used under normal operating conditions as intended by the manufacturer.