Portable Air Conditioner Owner’s manual For ACP-1400E/H Series
THANK YOU Thank you for choosing this innovative air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximize this product’s performance. SAFETY INSTRUCIONS IMPORTANT! • The unit is designed for indoor operation.
Do not use your air conditioner under the following conditions conditions:: • • • • • • • • • If the power cable wires are frayed or cut Where small children may be left unattended On a slope or uneven surface Close to a naked flame This product is not made for DIY repair If there is a risk of liquid falling on the unit Inside unit exposed to the weather outdoors Near water If an extension lead may become overloaded • Where the power cable may be damaged • Where it may be damaged by chemicals • Where ther
PARTS (1) (2) (3) (4) (5) (6) Front panel Air outlet Control panel Rear panel Right air inlet Castor ( OLD ) (7) Left air inlet (8) Hose connector (9) Exhaust hose (10) Drainage point with rubber water stopper ( NEW ) 5
ACCESSORY Exhaust Hose Hose Connector Telescopic Slide Bar Connector(NEW) Telescopic Slide Bar Connector(OLD) Telescopic Slide Bar Carbon Filter Water Container Remote Control 6
CONTROL PANEL LED Indicator Light 1 – Ionizer & UV indicator light in green 2 – Swing indicator light in green 3 – Timer indicator light in green 4 – Sleep mode indicator light in green 5 – Fan speeds a. Fast – indicator light in red b. Normal - indicator light in green c. Slow - indicator light in yellow 6 – Mode a. Cooling – indicator light in green b. Dehumidification – indicator light in yellow c. heat – indicator light in red d.
INSTALLATION WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another. In doing so keep this in mind: - - Ensure that the unit is positioned upright, on a level surface and 50cm away from any obstacles. Do not operate the unit inside the bathroom, shower, or in any other very humid environment. Slide the hose connector A in the hot air outlet.
IMPORTANT! The flexible exhaust hose can be extended from 500 to 1500mm for mounting. This length has been designed especially according to the specifications of the air conditioner. Do not use an extension or exchange for a different hose as that may cause the unit to malfunction. The exhaust air must flow freely; any blockage can lead to overheating of the air conditioner. Take care to prevent any sharp bow or bend in the exhaust.
Timer For all of the following TIMER programming, proceed firstly with these standard steps: • Press the button briefly, the 2 digits on the control panel will show 00. • Press the button again to program the timer for ON – when the unit is OFF or program the timer for OFF – when the unit is RUNNING. The time will be increased by hour from 00, 01, 02…..24, thence go back from 24, 23, 22…..00 by each press of the button. • Press the button briefly to adjust the time as 00 to cancel the timer function.
Ionizer & UV Press button to turn on the Ion & UV function. Press button to turn off the Ion & UV function. Air flow The moment the air conditioner is connected to the electricity, the louvers open then close and stay closed. • When the ON – button is pressed, the louvers open to maximum. • Press the button, the louvers will swing continuously up and down. • When the ON-button is pressed, the louvers open to maximum.
AIR FILTERS This air conditioner is equipped with two filter sets to clean the circulated room air: A screen filter in the both sides of the unit to remove dust particles Clean the air filters The screen filters should be cleaned regularly by rinsing them under running water. Note: When the unit is running for 100 hours, the 2 digits on the control panel will blink to remind you that the filter needs to be cleaned. Press and buttons simultaneously to turn off the blinking of 2 digits.
EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container. When the internal water container is full the beep will be alarmed in 15 times. The unit will switch off automatically and the water full indicator will be in red. To empty the water container do the following: • Switch off the unit and remove the plug from the wall socket. Do not move the unit. Doing this can result in water leakage, damaging your floor or carpet.
CLEANING WARNING! First of all switch off the unit and remove the plug from the wall Socket. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Clean the screen filter regularly with a vacuum cleaner. NOTE! Never use the air conditioner without the screen filter. STORAGE • Empty the internal water container. • Clean the screen filter. • Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry.
OTING TROUBLE SHO SHOO Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem The air conditioner does not function. Cause Solution Connect to a functioning outlet and switch No power supply. on. Timer function is active. Deactivate TIMER function. In direct sunlight. Close curtains.