User's Guide

Table Of Contents
Enter Setup
** Exit Setup 34
You may wish to restart the reread timeout when the scanner encounters the same barcode that was decoded in the last
scan session before the reread timeout expires. To enable this feature, scan the Reread Timeout Reset On barcode. This
feature is only effective when Reread Timeout is enabled.
Reread Timeout Reset On
** Reread Timeout Reset Off
Image Decoding Timeout
Image Decoding Timeout specifies the maximum time the scanner will spend decoding an image. This parameter is
programmable in 1ms increments from 1ms to 3,000ms. The default timeout is 500ms.
Image Decoding Timeout
Set the image decoding timeout to 1,000ms:
1. Scan the Enter Setup barcode.
2. Scan the Image Decoding Timeout barcode.
3. Scan the numeric barcodes “1”, “0”, “0” and “0” from the “Digit Barcodes” section in Appendix.
4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the Exit Setup barcode.