INSTALLATION INSTRUCTIONS ROMAN TUB 2 VALVE AND TRIM Valve Model No's: 1-677 Trim Kit for Model No’s: 3-2496, 3-2486 2001 CARNEGIE AVE, SANTA ANA CA 92705 (949) 417-5207 WWW.NEWPORTBRASS.
Rough-in Valve Installation Recommended Installation by a Professional Plumbing Contractor Note: Use plumbers tape or equivalent to seal all threaded joints. Warning: To prevent severe damage to valve body, any solder/braze process must be performed a min. of 4" from ports. 1. Install the quick connect spout shank through center hole of mounting surface. Secure with washer nut. See Fig. 1. 2. Place washer nut on valve body. Insert body, (blue cold & red hot), through hole from below mounting surface.
Trim Installation Note: To achieve desired handle rotational alignment, the cartridge MUST be tightened in a clockwise rotation only. The use of petroleum base plumbers putty on our products will nullify the warranty. We recommend the use of clear silicone sealing materials. (Cartridge factory torque is set @ 14-16 ft-lbs.) 4. Apply plumbers tape to spout nipple and install into quick connect spout shank. Slide spout base onto spout (re-grease if necessary).