Installation & Assembly

Recommended Installation by a Professional Plumbing Contractor
Note:
The use of petroleum base plumbers putty on our products will nullify the warranty.
We recommend the use of clear silicone sealing materials. Use Plumbers tape or equivalent
to seal all threaded joints. If mounting faucet to stainless steel rim, an under-mount support,
(e.g. wood, appropriate size x 1/2” thick), should be utilized.
Recommended deck hole Ø1.25. Drill holes in mounting surface, center spacing for bridge
faucet to be 8” and the side spray hole to be a minimum of 4-3/4” away from the nearest
mounting hole of faucet.
1. Place bridge faucet body through holes on mounting surface and secure into place with flange
nuts. Place shank with red paint into left side deck hole. See Fig. 1.
2. Attach the diverter assembly to shank - one side at a time (Cold block to the shank on cold
side) as follows: Reference Fig. 2
a. Engage stem connector on to broached stem extension, located inside shank.
See Detail A.
b. Rotate to align exterior hex of shank and interior hex of body then push up into
position.
c. Check the alignment of the pin groove of shank and slot in body. Secure position by
pushing quick release pin though slot and into groove. See Fig. 2.
d. Tighten the set screw to lock diverter in position. See Detail B.
3. Place the side spray escutcheon with shank through mounting surface and secure into place
with flange nut. See Fig. 3.
4. Drop side spray hose through escutcheon and thread onto diverter assembly. Do not use
the adapter provided with spray assembly. See Fig. 3.
5. Attach hot and cold water supply hoses (1/2-14NPS, not included) to appropriate valve,
(utilizing cone washers, friction rings and nuts - (not included)) See Fig. 4.
6. Adjust handle alignment as required by, removing set screws on handle base. Lift handle from
stem, rotate to proper alignment and lower back onto stem. Secure into place with setscrews.
7. Remove aerator from spout, turn on water supply, and flush valves until water is clear. Check
for leaks and make any final adjustments required. Re-attach aerator to the spout.
Important:
1. If the cold block of the diverter assembly is installed on the hot side of the faucet, the faucet
will have no flow.
2. Faucet can operate without side spray by replacing the side spray connection to cold block
with 1/4-18 NPMS or 1/4-18 NPT thread cap.
NWP-1400-5412