Specification Sheet

page 1 of 2 spec_ t: 949.417.5207 | www.newportbrass.com
©2014 Brasstech, Inc.
3-2044TS_rev-a
SECANT
Thermostatic Shower System Trim
Also 2-260, 3-368
3-2044TS
Features
Solid brass construction
Temperature-adjust handle for thermostatic valve
ADA compliant contemporary lever handle assembly for control valve
Intended for use with Newport Brass rough valve(s) as specified (Required Accessory)
Specied Model
Model Description Colors / Finishes
3-2044TS Thermostatic Shower System Trim
15 15A 26 10B Other
2-260 Optional Extension for Thermostatic Shower System Valve Trim
15 15A 26 10B Other
3-368 Shower System Control Valve Trim (Escutcheon/Handle)
15
15A
26 10B Other
Product Specication:
The Thermostatic Shower System Trim shall be made of solid brass construction. Thermostatic Shower System Trim shall include a
faceplate and temperature-adjust handle. Shower System Control Valve Trim(s) (Escutcheon/Handle) shall shall be ADA compliant when
used with specified Shower System Control Valve(s). Thermostatic Shower System Trim shall be Newport Brass Model 3-2044TR/____ and
Thermostatic Shower System Valve shall be Newport Brass Model 1-540. Shower System Control Valve Trim (Handle/Escutcheon) shall be
3-368/_____ and Shower System Control Valve(s) shall be 1-60____ (and 1-60____).
Add "Color / Finish" sufx to Trim model numbers, below.
3-2044TS
3-368
2-260
Codes / Standards Compliance
Meets or exceeds the following at date of manufacture:
ASME A112.18.1/CSA B125.1
IAPMO/cUPC
IPC
ADA
ICC/ANSI A117.1
ASSE 1016
All applicable US Federal and
State material regulations
Colors / Finishes
15:
15A:
26:
10B:
Other:
Polished Nickel
Antique Nickel
Polished Chrome
Oil Rubbed Bronze
Other
Trims, above, and Rough Valves, below, must all be specied.
Required Accessory:
Application Shower System Valve Shower System Control Valves
Description Thermostatic Flow Control (CCW Off) Flow Control (CW Off)
Inlet/Outlet Size 3/4" 1/2" 3/4" 1/2" 3/4" 3/4"
(20pt spline)
Part Number
1-540 1-606c 1-607c 1-606h 1-607h NA
Image
Note: The use of one 1-606H/C or 1-607H/C flow control valve and one 1-617 diverter valve can be configured to meet the requirements of CALGreen Bldg. Code (2010).