Installation

Setting the Temperature Limit Stop
This valve has an upper temperature limit stop , which can allow desired and
safe hot water temperature (recommended maximum is 110°F). This stop
may be adjusted once the valve is installed. Before making this adjustment,
run water with the valve turned to the hot setting. If the water temperature
is too high in this position, then perform the following adjustments:
1. Remove the trim (handle, escutcheon and cover).
2. Remove the all-thread nipple, (item 7), hex nut (item 9) and stem plate
(item 8).
3. Remove the broach stem (item 6) and the limit stop (item 5).
4. Close the valve by turning the cartridge stem clockwise
until it stops, (Illustration 4).
5. From the CLOSED position, rotate the cartridge stem counter-clockwise
until the desired temperature is achieved.(Illustration 5).
6. Place the limit stop (item 5) on the cartridge stem against the stop block
(Illustration 6). Rotate several times to make sure the stop is at the desired
temperature setting.
7. Install the broach stem (item 6), stem plate (item 8), all thread nipple
(item 7) and hex nut (item 9).(NOTE : For broach stem to be fully seated
onto cartridge, the all thread nipple (item 7) and hex nut (item 9) must be
tightly secured against the retaining plate).
Illustration 3
LIMIT STOP HITS
STOP BLOCK AT
HIGHEST
DESIRED TEM
PARATURE
Illustration 6
Illustration 5
Illustration 4
Page 3 of 4
NWP-1-684
Asm-1-281
BILL OF MATERIAL FOR ASM-1-281