Installation

III. Installing Trim
1. Remove and discard mud cover and screws.
2. Slide sleeve over valve body with grooved notch to topside.
3. Slide cover plate with gasket over sleeve and secure with decorative collar nut.(See Fig. 4).
4. Orient and position stop ring as shown below (See Fig. 5).
5. Open shut-off valve and verify water temperature at outlet device by using a thermometer.
NOTE: The safe and factory set temperature is 100°F. If the temperature needs to be adjust-
ed follow step 6, otherwise skip to step 7.
6. Rotate cartridge stem to adjust temperature:
(clockwise = colder or counterclockwise = hotter)
7. Place thermo bonnet onto cartridge stem with red button (100°F) positioned straight up and
inline with notch on the sleeve (See Fig. 6).Install thermo handle.
8.Install thermobonnet and then thermo and diverter handles (See Fig. 6).
Sleeve
Coverplate
Valve
Fig. 4
Stop ring
Cartridge stem
Fig. 5
Fig. 6
Bonnet
Handle
NWP-1-742
Decorative
collar nut
Optional Extension Kit
20-146 available