User Manual

Page | 46
FIGURE 27
FIGURE 28
A source Type selector drop-down at the
top of the Configuration panel (Figure
28) lists the Connection Type options
available for the corresponding input.
For most TriCasters, options include Mic
1, 2 (with and without phantom power),
Line, AES/EBU, and SDI Embedded.
After connecting audio sources to the input connectors (see also Section 3.5.1), the
first thing to do is set the correct Connection Type using the drop-down menu:
Select Mic 1, 2 for professional grade microphones or similar sources. Use
the Phantom option for condenser type microphones requiring
supplementary power.
Choose Line for most other device connections (including consumer devices
such as a CD player, computer audio output or VCR).
For 8-input models only , select AES/EBU for digital audio from an AES/EBU
(AES3) output.
SDI Embedded provides digital audio from an SDI video source.
Note: Analog audio levels conform to SMPTE RP-155. The maximum input/output level
is +24 dBu, nominal Mic input level +4 dBu (-20dBFS), and the sample rate is 96 kHz.