GEOSOFT 2.0 User Manual Geosoft2 (v1.1.
CONTENTS INTRODUCTION .........................................................................................................6 MENU SELECTIONS ..................................................................................................7 FILE MENU .................................................................................................................7 New ......................................................................................................................7 Open.............
ENTERING & EDITING VENUE................................................................................12 EDIT VENUE PLANES.................................................................................................12 Audience ............................................................................................................13 Annotation ..........................................................................................................13 Vertex 1 to 4 ..................................
GEO S8 CLUSTER MECHANICAL WINDOW..........................................................21 CONFIGURATION SETTINGS .......................................................................................21 Rigging Mode .....................................................................................................21 Wind Beaufort 8..................................................................................................21 Cluster Secured..........................................................
GEO D CLUSTER MECHANICAL WINDOW ...........................................................30 CONFIGURATION SETTINGS .......................................................................................30 Rigging top (case dependent, selectable) ..........................................................30 Rigging bottom (case dependent, automatic) .....................................................30 Chain lever hoist (selectable) .........................................................................
INTRODUCTION GEOSoft2 software is a R&D simulation tool derived application. It processes measured speaker data with complex mathematical algorithms to assist the user in designing vertical GEO Tangent Arrays that provide even SPL throughout the depth of the audience.
MENU SELECTIONS File Menu New Opens a blank file (GeoS Cluster, no venue information) Open Opens previously saved configuration filename.nexo Save Saves the configuration as previously saved filename.nexo Save As Saves the configuration as filename.nexo (approximate size : 50 KB). Import Geosoft 1 Projects Imports Geosoft 1 .MAT file (extends Geosoft 2D lines to 3D 2 meters width planes) Export Exports currently displayed window in a JPEG format (approximate size: 100 kB).
Edit Menu Add Cluster Adds Cluster (New Cluster Window) Duplicate Cluster Opens Offset Position Window, which allows x or y cluster mirroring and offset cluster duplication Delete Cluster Deletes Selected Cluster (Deletes selected Cluster Tab) Rename Cluster Renames Cluster Edit Cluster Positions Opens the Edit Cluster Window: Depth, x-pos when cluster flown, distance between top of first cabinet and venue geometry reference point 0 along X axis; when cluster stacked, distance between bottom of first cab
Height, z-pos when cluster flown, distance between top of first cabinet and venue geometry reference point 0 along Z axis; when cluster stacked, distance between top of first cabinet and venue reference point 0 along Z axis; Horizontal angle (Positive CCW looking from top) and Vertical angle (Positive going up) are for Cluster Orientation; Show Horizontal Coverage displays -6dB lines for selected cluster in Venue tab; these line are defined as the intersection between each cabinet nominal -6dB coverage tria
New Point Opens Spectrum Point Coordinates Input Window Edit Point Opens Selected Spectrum Point Coordinates Input Window for editing Delete Point Deletes Selected Spectrum Point Options Menu Meter / Feet Units Opens the Units Window: - Do Convert: when selected, switching from Meter to Feet (or vice versa) will not change Venue dimensions when unselected, switching from Meter to Feet (or vice versa) will not change numerical X/Y/Z values and will therefore scale up or down the venue.
Edit air absorption Opens the Air absorption parameters Window Important : please note that dBMIF curve remains unchanged with air absorption. 3D Mode / 2D Mode Switches project from 2D to 3D Mode or opposite (see above). “2D” or “3D” are displayed next to toolbar as a reminder. Help Menu Help Opens current GeoSoft Help Manual. Structural Analysis Opens NEXO Geo S8, Geo S12, Geo D or GeoT structural analysis PDF files.
ENTERING & EDITING VENUE 3D venue display Edit Venue Planes Opens tables to edit planes as below Edit Venue Planes Table 3D and 2D NEXO 12/38 154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14 Fax : +33 (1) 48-63-24-61 - Email : info@nexo.fr - Web : http://www.nexo-sa.com - S.A. au capital de 1.003.000 €. R.
Audience Seated is 1.20 meter height mapping Standing is 1.60 meter height mapping No audience disables acoustic computations on selected plane, however, plane is still be displayed in Venue (typically, ceilings, walls). Disabled disables both display and computations (this feature allows to enter various configurations in the same venue file) Annotation Annotation is Plane name Vertex 1 to 4 Vertex 1 to 4 are to enter 4 plane corners coordinates.
Add plane Adds a new plane (with empty coordinates) Duplicate plane Opens below window, which allows rotating (around origin) or offsetting defined plane. Delete Plane Deletes selected plane Invert Plane Reverses P1 to P4 in P4 to P1 for proper plane orientation Set Audience for all No audience / Seated / Standing / Disabled defined simultaneously for all planes Open Venue File Opens .txt file (Geosoft2 Venue text format), .
Edit Venue (2D Mode) When selecting « 2D Mode » in the Option menu, planes are defined by two points (X, Z) coordinates. Working in 2D mode is highly recommended for fast configuration definition since only 4 values are to be entered instead of 12 in 3D mode. Important: when switching from 3D Mode to 2D Mode, all clusters horizontal angles as well as venue Y coordinates will be lost.
PROJECT WINDOW Project Enter project name. Company Enter company name. Author Enter your name. Date Enter the date. Text Window Type your project comments here. NEXO 16/38 154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14 Fax : +33 (1) 48-63-24-61 - Email : info@nexo.fr - Web : http://www.nexo-sa.com - S.A. au capital de 1.003.000 €. R.
GEO CLUSTER ACOUSTIC WINDOW Cluster Type Flown / Stacked NEXO GEO S8, GEO S12, GEO D or GEO T clusters Speaker Quantity Defines quantities for: NEXO GEO S805 / S830 NEXO GEO S1210 / S1230 NEXO GEO D10 / GEO SUB NEXO GEO T4805 / NEXO T2815 / CD18 Insert / Remove This feature is accessible by right-mouse clicking while in the Inter-Angle page, or by positioning cursor where a speaker needs to be inserted or removed and then changing the speaker quantity.
Rig Angles Tab Vertical Angle Configuration Horizontal Dispersion Configuration Choices between the cabinets are : GEO S8 - S805 to S805 : 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 degrees ; - S805 to S830 : 17.5 degrees ; - S830 to S830 : 17.5 -30 degrees ; GEO S12 - S1210 to S1210: 0.20 - 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 – 6.25 – 8.00 – 10 degrees ; - S1210 to S1230: 16 degrees; - S1230 to S1230: (16) - 22.
CDD Allows to define horizontal coverage for each cabinet (GeoS8, Geo S12 and Geo D) Cluster Position Mouse Click inside the frame opens the Cluster Position Window (see above) Pressure Plot and Frequency Response display Pressure plot Displayed Pressure Levels curves are selectable and are : - dBMIF, stands for dB “Make It Flat” ; for proper array curvature definition, this curve has to fit within 3 dB on the audience area.
Frequency Response Frequency plot becomes available by selecting “Show Spectrum” in the Spectrum Menu (or Right Mouse Click on Side View. Points for which frequency response will be computed are defined by Right Mouse clicking on Side View. SP Point window allows then to enter coordinates. Curves can be displayed Continuous, Octave Bands, 1/3rd Octave Bands or 1/6th Octave Bands. Plots can be stored in memory by double-clicking on the point coordinates below display scrolling menu.
GEO S8 CLUSTER MECHANICAL WINDOW Configuration Settings Rigging Mode NEXO GEO S8: - Bumper Only (GeoS8 without CD12) - Extension Bar at the back (GeoS8 without CD12) - Extension Bar at the Front (GeoS8 without CD12) - CD12 Link Bar (GeoS8 with CD12 Only) Wind Beaufort 8 Corresponds to a 20.7 m/s wind. Options are: - No Wind - Wind from the back of the cluster - Wind from the front of the cluster Lateral wind is considered to have no influence on investigated forces.
Cluster Dimensions and Weight - Cluster Type : as in Acoustic Page - GEO Quantity: as in Acoustic Page - CD12 Quantity: as in Acoustic Page - Bumper Angle: Angle in relation to Horizontal Line, CCW.
Mechanical Forces - Allowed Loads on Bumper Rear Points S1: theoretical pressure/tensile force values confirmed with destruction tests - Applied Loads on Bumper Rear Points S1: configuration applied value (turns red if outside limits) - Allowed Loads on Bumper Front Points S2: theoretical pressure/tensile values confirmed with destruction tests - Applied Loads on Bumper Front Points S2: configuration applied value (turns red if outside limits) - Allowed Moment on Extension Bar (closed cross-sectio
Working Load – Safety Factor – Lifting Factor Percentage of Allowed Working Load Is based on the ratio of all applied moments and forces to their limit Is determined by the component which is the closest to its limits Corresponds to a Safety Factor of 1.5 when is equal to 100% Must not be above 100% (turns red if so) Safety Factor for 100% of Allowed Working Load Cluster configuration Safety Factor Must not be below 1.5 (turns red if so) Can be used to comply with local regulations Lifting Factor Is 1.
Cluster Drawings Drawings are displayed to show computed points and cluster setup configurations.
GEO S12 CLUSTER MECHANICAL WINDOW Configuration Settings Single Motor / One Rigging Point Two Motors / Two Rigging Points Rigging Mode NEXO GEO S12: - One motor or - Two motors Rigging point position - When using one motor, gives the bumper hole position to achieve required bumper angle (turns red if gravity center is off hole range, turns orange when 5% to the limit).
Cluster Dimensions and Weight Single Motor / One Rigging Point Two Motors / Two Rigging Points - Cluster Type : as in Acoustic Page - GEO S1210 Quantity: as in Acoustic Page - GEO S1230 Quantity: as in Acoustic Page - Bumper Angle: Angle in relation to Horizontal Line, CCW.
Mechanical Forces Not implemented at this time Angle Sequence - Delta: Inter Cabinets Angle Sequence - Sum: Cumulative Angle Sequence (which takes wind effect into account) Working Load – Safety Factor – Lifting Factor Not implemented at this time Caution – Warning Messages Warning Messages for Rigging feasibility and safety. Permanently displayed messages Conditional messages These messages are related to unfeasible loads: Please note that safety warnings are not implemented at this time.
Cluster Drawings Drawings are displayed to show computed points and cluster setup configurations. A C1 A1 C2 A2 C1 C2 R R1 fb R2 S2 F S1 F1 fb S2 F2 S1 f1 f1 Fw Fw GC f2 GC f2 f3 f3 f4 f4 f5 f5 D D NEXO 29/38 154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14 Fax : +33 (1) 48-63-24-61 - Email : info@nexo.fr - Web : http://www.nexo-sa.com - S.A. au capital de 1.003.000 €. R.
GEO D CLUSTER MECHANICAL WINDOW Configuration Settings Rigging top (case dependent, selectable) 1 Motor + EXBar1: GEO Bridle + GEOD bumper + Short Extension Bar + Wheel (only for GEO D clusters) 2 Motors + EXBar1: GEOD bumper + Short Extension Bar (only for GEO D clusters) 2 Motors + EXBar2: GEOD bumper + Long Extension Bar (for GEO D and GEO SUB clusters) Rigging bottom (case dependent, automatic) Bottom-Bumper: GEOD bottom bumper (only for GEO D or combined GEO D / GEO SUB clusters) Bumper + ExBar3: GEO
Cluster Dimensions and Weight (2 rigging points) - Cluster Type : as in Acoustic Page - GEO SUB: as in Acoustic Page - GEO D10: as in Acoustic Page - Bumper Angle: Angle in relation to Horizontal Line, CCW.
Mechanical Forces - Allowed force on bumper front rigging point R2: theoretical tensile force value limit - Applied force on bumper front rigging point R2: applied value (turns red if outside limits) - Allowed force on bumper rear rigging point R1: theoretical tensile force value limit - Applied force on bumper rear point rigging R1: applied value (turns red if outside limits) - Allowed force on bumper front connecting point to top cabinet S2: theoretical pressure/tensile force value limit - App
Cluster Dimensions and Weight (1 rigging point) - Cluster Type : as in Acoustic Page - GEO D10: as in Acoustic Page - Bumper Angle: Angle in relation to Horizontal Line, CCW.
Mechanical Forces - Allowed force on bumper front rigging point R2: theoretical tensile force value limit - Applied force on bumper front rigging point R2: applied value (turns red if outside limits) - Allowed force on bumper rear rigging point R1: theoretical tensile force value limit - Applied force on bumper rear point rigging R1: applied value (turns red if outside limits) - Allowed force on bumper front connecting point to top cabinet S2: theoretical pressure/tensile force value limit - App
Angle Sequence - Delta: Inter Cabinets Angle Sequence - Sum: Cumulative Angle Sequence Working Load – Safety Factor – Lifting Factor GeoD cluster - Percentage of Allowed Working Load Is based on the ratio of all applied moments and forces to their limit Is determined by the component which is the closest to its limits Corresponds to a Safety Factor of 4 when is equal to 100% Must not be above 100% (turns red if so) GeoD cluster - Safety Factor for 100% of Allowed Working Load Cluster configuration Safe
Caution – Warning Messages Warning Messages for Rigging feasibility and safety. Permanently displayed messages Conditional messages These messages are related to unfeasible or unsafe loads: Cluster Drawings Drawings are displayed to show computed points and cluster setup configurations. NEXO 36/38 154 allée des Erables - BP 50107 - 95950 ROISSY CDG CEDEX – France - Tel : +33 (1) 48-63-19-14 Fax : +33 (1) 48-63-24-61 - Email : info@nexo.fr - Web : http://www.nexo-sa.com - S.A. au capital de 1.003.000 €.
GEO T CLUSTER MECHANICAL WINDOW Configuration Settings Rigging Mode NEXO GEO T - Bumper Only (Tension Mode) - Bumper + Half Kelping Beam (Tension mode), which allows greater distance between rigging points - Compression Mode + 20° Kelping Beam - Compression Mode + Half Kelping Beam Wind Beaufort 8 Corresponds to a 20.7 m/s wind.
Cluster Dimensions and Weight - Cluster Type : as in Acoustic Page - GEO Quantity: as in Acoustic Page - CD18 Quantity: as in Acoustic Page - Bumper Angle: Angle in relation to Horizontal Line, CCW.
Mechanical Forces - Allowed load on selected bumper rear rigging point R1: theoretical tensile force value limit - Applied load on selected bumper rear rigging point R1: configuration applied value (turns red if outside limits) - Allowed load on selected bumper front rigging point R2: theoretical tensile force value limit - Applied load on selected bumper front point rigging R2: configuration applied value (turns red if outside limits) - Allowed pressure/tensile loads on T4805 rear point S1: theor
Angle Sequence - Delta: Inter Cabinets Angle Sequence - Sum: Cumulative Angle Sequence Working Load – Safety Factor – Lifting Factor GeoT cluster - Percentage of Allowed Working Load Is based on the ratio of all applied moments and forces to their limit Is determined by the component which is the closest to its limits Corresponds to a Safety Factor of 4 when is equal to 100% Must not be above 100% (turns red if so) GeoT cluster - Safety Factor for 100% of Allowed Working Load Project configuration Safe
Caution – Warning Messages Warning Messages for Rigging feasibility and safety. Permanently displayed messages Conditional messages These messages are related to unfeasible or unsafe loads: Cluster Drawings Drawings are displayed to show computed points and cluster setup configurations.