Install Manual
Tighten battery terminals securely with pliers.
Terminals should NOT be just finger tight!!
Use cable ties sparingly to secure all
pump and sensor cables along PVC.
Make sure cables DO NOT interfere
with sensor operation!!
Install multiple batteries in
****PARALLEL ONLY!!
DO NOT CONNECT BATTERIES IN SERIES!!
or
****Damage to unit will result!!
After installation is complete, verify battery type, battery
amp hours, mode type and turn on battery charger. This
is done in the Configuration Menu.
Both sensors must be higher than the
intakes of BOTH PUMPS if stacked.
Install gray sensor as ‘Sensor 1’ and white
sensor as ‘Sensor 2’.
Install ‘Sensor 2’ at least four to six inches
above ‘Sensor 1’.
Sensor 1 (Gray)
SS mounting clamps used to attach the sensor bracket to the
PVC.
Drill a 1/8” air relief hole in each vertical discharge PVC pipe.
Angle the drill hole downward, so water will spray into the pit area
and position the hole about 2 inches above the top of the elbow.
Use ONLY a 1/8” drill bit!!
DO NOT DRILL INTO THE PUMP OR THE ELBOW!!
Sensor 2 (White)
Installation Guide