If Notification is installed
Notification will occur on AC Power loss after approximately thirty minutes.
Clear AC Power Alerts
AC power alerts will clear automatically when condition is corrected.
AC Power Loss
If the NexPump is alerting about an AC Power loss and there is not an issue with the AC Power in your household, you should
check the electrical outlet the NexPump AC Power cord in plugged into with a portable device to check if the electrical outlet is
live. If the electrical outlet is live then there may be an issue with the internal power supply in the NexPump system unit.
IMPORTANT: The power supply is not field serviceable. Do not attempt to disassemble the NexPump or power supply.
Testing
The NexPump schedules an automatic self-test every 12 hours. A
manual test can be done by selecting the menu manual self-test. The
self-test feature will test pumps, battery, electronics, etc. To run a
manual self-test use the up, down arrows and select the menu manual
self-test by pressing ENTER.
Resetting the self-test time can be found in the reset menu or can be
performed with command console on internet versions. Resetting
should be performed at the time you want the self-test to begin.
Once reset the automatic self-test will start at the new time.
To change the self-test time of the system use the left and right
arrows to adjust the time. When on desired time press ENTER to set.
The system self-tests every twelve hours so this will be the time for
AM and PM.
Battery
Battery Specifications
The NexPump requires a deep-cycle marine battery. A 105 amp hour or greater rating is required. This is usually a group 27 or
group 31 deep-cycle marine battery.
Multiple Batteries:
Two batteries may be connected in PARALLEL to increase time on battery power. This configuration is highly recommended.
IMPORTANT: DO NOT CONNECT BATTERIES IN SERIES. CONNECTING MULTIPLE BATTERIES IN SERIES WILL
DAMAGE THE UNIT AND VOID THE WARRANTY.
Testing
Battery is tested on 12 hour self-tests or manual tests. Exceptions: Charge system is active, battery disconnected or battery
replacement alert is active.
If Notification is installed
Notification will occur on a battery disconnected or low battery or battery replacement alert after approximately five (5) minutes.
After an AC Power Outage when running on battery, Notification will occur after approximately thirty (30) minutes.