Pressure Injection Cell Operator’s Manual
Operator’s Manual for the Pressure Injection Cell Operator’s Manual Pressure Injection Cell CONGRATULATIONS! Congratulations on your purchase of a Next Advance Pressure Injection Cell. Please read this operator’s manual which explains proper operation of the instrument. This manual can alsobe viewed on the web at http://www.nextadvance.com/public/file/Press _Inject_Cell_PC77_manual.pdf Enjoy using your Pressure Injection Cell.
Operator’s Manual for the Pressure Injection Cell PARTS OF THE PC77-MAG PRESSURE INJECTION CELL Bolt Knob Nut Vent Teflon Ferrule (under the nut) Top Base 3-Way Valve Inlet Magnetic Stirplate SYMBOLS USED ON THE PC77- MAG MODEL WITH STIRPLATE ON position of the Power Switch. OFF position of the Power Switch Caution: Follow the Instructions in the Operator’s Manual This product complies with the European Low Voltage and EMC Directives.
Operator’s Manual for the Pressure Injection Cell SETTING UP YOUR PRESSURE INJECTION CELL Setting up the Pressure Injection Cell consists of attaching it to 1/8 inch (outside diameter) thick walled stainless steel tubing (not supplied with the PC77 Pressure Injection Cell). First, slide the tubing through the inlet nut until it hits a stop. Finger tighten the nut and then tighten it with a wrench for 1-1/4 turns. Connect the other end of the tubing to a pressurized gas tank. It is now set up.
Operator’s Manual for the Pressure Injection Cell desired pressure. When the injection is finished, close the gas tank valve. Then turn the knob on the 3-way valve so that it points toward the vent. This depressurizes the injection cell. Now you can loosen the nut over the ferrule and remove the capillary, loosen the three bolts, remove the top, and remove your sample tube. sample tubes will protrude above the surface, making placement and retrieval easy.
Operator’s Manual for the Pressure Injection Cell TROUBLESHOOTING SPECIFICATIONS In addition to the tips given below, a thorough list of troubleshooting tips is at http://www.nextadvance.com/api/index.cfm/c ms.page/i/5063/pressure-injection-cell-troubl eshooting. If gas leaks through the top-base interface of the pressure injection cell, the three bolts might not be fully tightened or the O-ring might be nicked or dirty or missing.
Operator’s Manual for the Pressure Injection Cell documentation of proper maintenance, if applicable. Next Advance makes no other warranty, express or implied, with respect to its Products. NEXT ADVANCE MAKES NO WARRANTY RESPECTING THE MERCHANTABILITY OF THE PRODUCTS OR THEIR SUITABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE. Next Advance shall not be liable for, indirect, special, incidental or consequential damages of any nature.