NP-610X X86 CISC-based Operator Interface Terminal with 10.
Copyright .................................................................................................................. 3 Safety Instructions..................................................................................................... 4 Chapter 1 Introduction............................................................................................... 5 1.1 Introduction ...................................................................................................
Copyright This document is copyrighted January l, 2008, by IVC Displays, Inc. All rights are reserved. IVC Displays, Inc. reserved the right to make improvements to the products described in this manual at any time. Specifications are thus subject to change without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of IVC Displays, Inc.
Safety Instructions Overview This section states the safety instructions, which must be followed when installing, operating and servicing the NP-610X. If neglected, physical injury and death may follow, or damage may occur to controller and related equipment. The material in this chapter must be studied before attempting any work on, or with, the unit. Warnings and Notes This manual distinguishes safety instructions.
Chapter 1 Introduction 1.1 Introduction The MT612X is a miniature and compact platform that has excellent system performance and function. The x86 CPU Core provides the maximum compatibility with the vast amount of Internet content available while the intelligent integration of several other functions, including graphics, makes the AMD Geode™ LX processor a true system level multimedia solution. The NP-610X has a 10/100 Base-T Ethernet port for responsive open communications.
• On-board 512MB DDR-400MHz SDRAM • • 44-pin IDE Interface (Disk-On-Module) 3 serial ports (2-RS232, 1-RS485 2W/4W) • • 2 USB ports full-speed port (12Mbps) 1 Ethernet port (10/100 Base-T) • • AC ‘97’ 16 bit sound output Built in RTC • • NEMA4 / IP65 Front Panel Power input: 24 VDC, 0.8A maximum • • Dimensions: (W x H x D): 259 x 201 x 51mm Weight: 1.6 KGs (3.52 lbs.
• Resolution: continuous • • Light transmission: above 80% Life: 1 million activation minimal Environmental Specifications • • Operating temperature: 0° ~ 45°C (32° ~ 113°F) Relative humidity: 10% ~ 90% @ 40°C, non-condensing • • Shock (operation): 10 to 25Hz(X,Y,Z direction 2G 30minutes) EMI: Complies FCC class A • • CE: Complies with EN50081-2 and EN50082-2 standards Front panel meets NEMA4 / IP65 Operating Systems • • Windows CE 5.0 .
Chapter 2 Installation Instructions 2.1 Mounting Instructions 2.1.1 Location Considerations Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC output modules, contactors, starters and relays, and any other source of electrical interference are located away from the back of the unit. Particular note should be taken to the position of variable speed drives and switching power supplies. Their input and load cables should be screened to a central star earth point.
2.1.3 Environmental Considerations The NP-610X are to be used indoors as built in displays. Make sure that the displays are installed correctly and that the operating limits are followed (See Specifications). Do not operate the unit in areas subject to explosion hazards due to flammable gases, vapors or dusts. The unit should not be installed where fast temperature variations and/or high humidity are present. This will cause condensation of water in the device.
2.2.1 Power Requirements Power The NP-610X can be powered by DC power only. The specified voltage range is +21 to 25 Volts DC. This insures compatibility with most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a switching power supply. The peak starting current can be as high as 700mA. Fusing Requirements If the display does not come on within 2 seconds of power up, remove power.
clockwise until it’s tight. Connect positive DC line to the ‘+24V’ terminal and the DC ground to the ‘GND‘ terminal. FUSE Replacement: The fuse use on MT608 is: BUSSMANN Fast Acting, Glass Tube Rating: 250VAC, 1A Size: 5x20mm Warning: 1. Make sure the power off before replace the fuse. 2. Do not replace the fuse with a different rating fuse. 2.2.2 Grounding Requirements Chassis ground must be used. DC ground is not directly coupled to Earth ground internally.
2.2.4 Safety Guidelines This section presents recommended installation practices, and procedures. Since no two applications are identical, these recommendations should be considered as guidelines. Hardware Considerations WARNING! The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition.
The ICS 3-304.81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association from NEMA ICS 3-304 2.3 Communications Connections The ports as you look at the back of the case, are the ports for connecting to a PLC or some external device (Controller Connectors). Cable Different cables are required for various devices.
2.3.1 Connector COM 1 [RS232] 2.3.
COM3 [RS-485] connect RS-485 2 wire Device COM3 [RS-485] connect RS-485 4 wire Device NP-610X COM1 [RS-485] 9P D-SUB Female RS-485 2 wire Device 4 Data+ Data+ 5 Data- Data- 1 GND NP-610X COM1 [RS-485] 9P D-SUB Female RS-485 4 wire Device 1 Rx- Tx- RS485 Transmit 2 Rx+ Tx+ RS485 Transmit 3 Tx- Rx- RS485 Receive 4 Tx+ Rx+ RS485 Receive 5 GND 2.3.3 USB Master port The USB Master port can connect USB mouse and USB keyboard. The USB Master port support USB 2.
2.4 CE Requirements EU directives that apply to the NP-610X Series: EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC) electromagnetic emissions and immunity Machinery Directive (89/392/EEC, 91/368/EEC, 93/44/EEC, 93/ 68/EEC) machine safety NP-610X products will be CE-marked to indicate compliance with the EMC Directive. The NP-610X Series has been designed to operate satisfactorily in electromagnetic noise (immunity) and without emitting high levels of electrical noise into the environment (emission).
Dimensions of NP-610X Cutout dimensions: NP-610X: 352mm [13.86”] W x 279mm [10.
Chapter 3 Windows CE.NET 3.1 Introduction The NP-610X series operator interface terminal is designed to serve on the Windows CE platform. Windows CE .NET is the successor to Windows CE 3.0. Designed from the ground up for the embedded marketplace, Windows CE .NET delivers a robust real-time operating system for rapidly building the next generation of smart mobile and small footprint devices. With a complete operating system feature set and end-to-end development environment, Windows CE .
3.2.2 System Settings NP-610X provides an integrated utility for users to make basic setting of the machine. Step 1. Tap the “cecp” icon from Desktop. 2. Launch the System Settings Control Panel.
Touch Screen settings The touch screen calibration can be executed from the Control Panel. Step 1. Launch the System Settings Control Panel. Tapping the “Calibrate” button. The screen will display a “+” sign at the center of the screen. Use a stylus or finger to push the center of the “+” until it moves. The “+” moves to upper-left, lower-left, lower-right and upper-right corners. When all five “+” are done the “+” will disappear. The Touch Screen parameter will store at Flash Rom.
“LCD Settings” page of the cecp provides the function to turn off the LCD backlight, and thus elongates the period of service. For example, if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used. The user must select “10 minutes” in the put down box and then press “OK” button. Then the screen save function is enabled. Once the backlight was turned off, events or perturbations from the touch screen can turn it on.
MAC address The MAC address page the block shows the network MAC address. Save Tap the Save registry button, would save the registry data to the Hard Disk folder. Next time reboot the NP-610X, Windows CE system will use the stored registry data. System version Show current CE image version. Set serial port mode Set Com1 mode. Select RS232/RS485 2wire or 4wire mode. Set Com3 RS232/RS485 mode. The serial port mode can be saved by “Save registry”.
Contrast Adjust the LCD contrast. 3.2.3 Hard Disk The Hard Disk serves as a small capacity hard disk. You can store your data and application in the D.O.M. via Hard Disk function to prevent unexpected loss of data as power failure. When power is shutdown and cold boot, the data in the D.O.M area is saved. 3.2.4 Startup After the system boot up, the startup execution function would automatically perform. This function is useful for control system to do the initialization processes or some other programs.
make a shortcut and copy it to "Hard Disk\StartUp". A shortcut can execute a program with Parameters. Follow the following procedure to create the shortcut (.lnk) file. A .lnk file is a text file that contains the command line for the linked target, which may be enclosed in double quotation marks, along with the length of that command line. Optionally, you can also pass parameters into the linked target. For example, to start MyApp.exe and pass two optional parameters into the application, a sample MyApp.
To create a new Remote Desktop Connection 1. Open Remote Desktop Connection. 2. In Computer, type the computer name for your computer running Windows XP Professional that has Remote Desktop enabled and for which you have Remote Desktop permissions. 3. Click Connect. The Logon to Windows dialog box appears. 4. In the Logon to Windows dialog box, type your user name, password, and domain (if required), and then click OK.
3.3 NP-610X Networking 3.3.1 Networking via Ethernet The NP-610X is equipped with a 10/100Base-T Ethernet controller. To utilize it, change the device name when the NP-610X is first turned on. Step 1 Click “Start/Settings/Control Panel” 2 Double click “Network and Dial-up Connections” 3 Find the default device name. Change it to a unique one depending on the plan CS89501 of individual LANs. 4 If the NP-610X is a node of a LAN with DHCP servers, it is now available.
6 Use the cecp utility “Save registry” to save this changed. 3.3.3 Web browser The NP-610X built-in Windows CE OS includes Microsoft Pocket Internet Explorer. It can be used to browse web pages on World Wide Web via LAN or dial-up connection.
3.4 Application program development The NP-610X is bundled with built-in Windows CE operating system. In real applications users need to execute various applications programs on it. However, unlike its other family the Windows CE is a hardware-dependent operating system. That is to say, Windows CE application programs are only portable in the source code level. Users must rebuild the runtime file for a different Windows CE platform even though the source code may not be changed at all.
3.5 Print NP-610X support PCL language printer. You can connect a PCL printer at USB Host port or via Network connect to a shared printer. From Internet Explorer or user’s application menu click “File” > ”Page Setup…” will appear print setup dialog. After the “Page Setup…”, click “File” > “Print”, printer will print out the data.
Desktop PC shares the printer.