USER MANUAL Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model 243007 Model 243008 NEXEL® 1-Door Reach-in Refrigerator NEXEL® 2-Door Reach-in Refrigerator For questions, please contact NEXEL® Customer Service at 1-800-245-6682 or visit www.nexelwire.
WARNING DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. PELIGRO - RIESGO DE INCENDIO O EXPLOSIÓN. CONTIENE REFRIGERANTE INFLAMABLE. DEBE SER REPARADO SOLAMENTE POR UN PERSONAL DE SERVICIO CALIFICADO. DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE FRIGORIGENE.
SPECIFICATIONS Model 243007 Dimensions (with casters) Number of Doors Number of Shelves Casters Capacity (Cubic Ft.) HP Voltage Amps Plug Type Temperature Range Exterior Construction Interior Construction Shelf Construction Refrigerant Unit Weight Hertz Phase Cord Length Lighting Warranty Model 243008 29"W x 32.2"D x 82.5"H 1 3 (4) 3" PP Swivel (2 locking) 23 1/4 115 3.6 NEMA 5-15P 33°F to 40°F 430 Stainless Steel Aluminum Epoxy-Coated Steel R290 282 lbs. 60 Hz 1 8 ft.
Model 243008 INSTALLATION Read this entire manual thoroughly prior to equipment set-up, operation and/or maintenance. IMPORTANT: If the refrigerator has recently been transported on its side, allow the unit to stand upright for a minimum of 24 hours before plugging it in. Make sure all shelves and accessories are properly installed before plugging in the unit. Do not attempt to remove or repair any component of the unit. Consult an authorized service technician for all servicing and repair needs.
Avoid installation in high humidity and/or dusty areas. High humidity can cause the unit to rust and may decrease efficiency. Dust collected on the condenser coil may cause unit to malfunction. Select a location away from heat and moisture-generating equipment. High ambient temperatures may cause the compressor to malfunction. Electrical Warnings Ensure that the required voltage is being supplied at all times.
LED MODE INDICATES On Compressor Enabled Flashing Anti-Short Cycle Delay Enabled (AC Parameter) On Defrost in Progress Flashing Dripping in Progress On Fans Output Enabled Flashing Fans Delay After Defrost On Measurement Unit Flashing Programming Mode NOTE: Your new refrigerator is already factory-set to run at optimum temperatures for food safety and should require no adjustments. Your refrigerator is set to cycle between a minimum temperature of 33°F and a maximum temperature of 40°F.
OPERATION/MAINTENANCE NOTE: It is strongly recommend that any servicing be performed by an authorized service technician. During maintenance and cleaning, please unplug the unit. LOADING PRODUCTS Do not block the inside air duct/fan at the top of your refrigerator. Maintain a minimum clearance of 4” between products and the fan at all times. Ensure all shelves are level and properly secured prior to loading products. Do not store flammable and/or explosive gas or liquids inside the unit.
TROUBLESHOOTING PROBLEMS CAUSES SOLUTIONS Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker. Power cord unplugged. Plug in power cord. Thermostat set too high. Set thermostat to lower temperature. Cabinet in defrost cycle. Wait for defrost cycle to finish. Thermostat is set too high. Set thermostat to lower temperature. Airflow is blocked. Re-arrange products to allow for proper air flow. Make sure there is at least four inches of clearance from the fan.