Installation Guide
 34 
 COLUMN WRAPS FROM FLUSH CORNERS, Cont. 
The Sandstone 18" Column Wrap cap is designed to fit over the columns if 
the top course of corners ends with the screw hems attached or with the 
screw hems removed.  
Screw Attachment: Dr ive one scr ew per  side thr ough the bottom lip of the cap all 
the way into the substrate. Be Careful to angle the Screws so they don’t run through the 
top of the cap.  
Do not overdrive screws.  
Adhesive Attachments:  
1)  If the top course ends with the screw hem attached:  
Place adhesive in each corner of the cap and secure. (Fig. 1).  
2) If the top course of corners has the screw hems cut off, face screw each piece 
1" from the top so that the cap covers the screw heads. Place adhesive on inside  
cutouts as shown (Fig. 2).  
Top Course with Screw Hem Attached 
Adhesive 
Points 
Bottom of Cap 
Top Course with Screw Hem Removed 
Adhesive 
Points 
Bottom of Cap 