Installation Guide

34
COLUMN WRAPS FROM FLUSH CORNERS, Cont.
The Sandstone 18" Column Wrap cap is designed to fit over the columns if
the top course of corners ends with the screw hems attached or with the
screw hems removed.
Screw Attachment: Dr ive one scr ew per side thr ough the bottom lip of the cap all
the way into the substrate. Be Careful to angle the Screws so they don’t run through the
top of the cap.
Do not overdrive screws.
Adhesive Attachments:
1) If the top course ends with the screw hem attached:
Place adhesive in each corner of the cap and secure. (Fig. 1).
2) If the top course of corners has the screw hems cut off, face screw each piece
1" from the top so that the cap covers the screw heads. Place adhesive on inside
cutouts as shown (Fig. 2).
Top Course with Screw Hem Attached
Adhesive
Points
Bottom of Cap
Top Course with Screw Hem Removed
Adhesive
Points
Bottom of Cap