Technical Drawings

MODEL E-500 DIAGRAM FRAMING DIMENSIONS
NOTES:
1. ALL MEASUREMENTS SHOWN IN INCHES WITH CENTIMETERS SHOWN INSIDE [ ]
2. MOUNTING LOCATIONS SHOWN CAN BE FOUND ON ALL SIDES AND CORNERS OF THE INSTALLATION BRACKET
3. INFORMATION PERTAINING TO THE CEILING CAN BE FOUND ON THE THIRD PAGE OF THIS DIAGRAM
4. COLORS SHOWN IN THIS DIAGRAM ARE FOR CLARITY ONLY, MECHANISM IS GREY POWDER COATED STEEL AND ALUMINUM
5. FRAMING TO BE DONE BY A LICENSED CONTRACTOR AND ELECTRICAL HOOKUP INSTALLED PER AUTHORIZED BUILDING CODES
QUICK REFERENCE DIMENSION GUIDE
MINIMUM FRAMING DIMENSIONS (W x L x H) = 32.125” [81.6] x 29.875” [75.9] x 13.5” [34.3]
PAGE 2 OF 3
COPYRIGHT 2018 - ALL RIGHTS RESERVED
UPDATED 01/26/18
MINIMUM REQUIRED
INSTALLATION HEIGHT = 13.5" [34.3]
A
A
FRONT VIEW
INSTALLATION BRACKET HEIGHT = 3.00" [7.6]
SIDE VIEW - A
TRUSS OR FRAMING
CEILING MATERIAL
MINIMUM FRAMING LENGTH = 29.875" [75.9]
MINIMUM FRAMING WIDTH = 32.125" [81.6]
INSTALLATION BRACKET THICKNESS = 1.50" [3.8]
FRONT/BACK
FRONT/BACK
MOUNTING LOCATIONS