Technical Specs

PAGE 2 OF 3
COPYRIGHT 2019 - ALL RIGHTS RESERVED
UPDATED 10/30/19
NOTES:
1. TOP SUPPORT BRACKETS ALLOW LID PLATE TO BE ADJUSTED FLUSH WITH TOPSIDE OF LID
2. LID IS DESIGNED TO FLOAT WITH PROVIDED SPRING LOADED PINS - LID MUST BE INSTALLED PROPERLY FOR SAFETY
MODEL L-75ix DIAGRAM REFERENCE CABINET DIMENSIONS
JOIST
JOIST
CEILINGCEILING
0.5" X 45 DEGREE LID BEVEL
LID
LID PLATE WIDTH = 30" [76.2]
MINIMUM CLEARANCE = 0.75" [1.9]
SIDE OF ENCLOSURE
ACTS AS LID CATCH
FRONT PANEL MUST BE
REMOVABLE FOR SERVICE
SPRING LOADED PIN
DO NOT BOLT LID TO LID PLATE,
USE PROVIDED HARDWARE
MINIMUM LID THICKNESS = 0.75" [1.9]
INSIDE OF CABINET
TO BOTTOM OF REAR
SUPPORT = 18.875" [47.9]
BACK OF CABINET
TO BACK OF TV = 9" [22.9]
TOP PANEL THICKNESS = 0.75" [1.9]
MINIMUM CLEARANCE = 1" [5.1]
MINIMUM CLEARANCE = 1" [5.1]
MINIMUM SEAM = 0.125" [0.3]
PRE-INSTALLATION BRACKET