Operation Manual
110 
Control Tab 
The Control Tab is used to configure the management Ethernet ports in the B264. This includes 
both the IP information, as well as the SNMP parameters. The Control Tab is only displayed for 
the B264. 
The B264 has two physical management (control) Ethernet ports. However, from a logical 
standpoint, they are a single port with a single IP address; the two connections are provided for 
control redundancy. If one port loses link, the unit can still be controlled from the other. If you 
do not need control redundancy, you can leave one of the ports disconnected. The unit will 
automatically and dynamically select the control port as follows: 
  If only one port has link, that port will be used for control. 
  If both ports have link, but at different speeds, the port with the highest speed will be 
used for control. 
  If both ports have link at the same speed, Port 1 will be used for control. 
Both ports support operation at 10, 100 and 1000 Mb/s, both half-duplex and full-duplex, with 
auto-negotiation and auto-crossover detection. 
The Control Tab has two bottom tabs: 
  Control Port is used to configure the IP parameters of the control port. 
  SNMP is used to configure the SNMP parameters for the unit. 
Control Port Configuration Tab 
The control configuration window is depicted below: 