Installation Instructions

11 – English
A.7 - Assigning a command (“Open” or “Step-by-step”) to a single button panel
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
PRG
(x 1)
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 3 movements.
4 5
...
= 5 sec
2
Select one of the following potions and execute it:
• option A = sets the “OPEN” command.
• option B = sets the “STEP-BY-STEP” command.
Hold down the button and release it after 5 seconds; count 2 movements.
A
A.6 - Adjusting the motor’s sensitivity to obstacles
NOTES AND WARNINGS
• Use this procedure to activate, adjust or deactivate the safety system that: a) detects the presence of an obstacle along the travel of the awning; b) reduces the mo-
tor tension on the awning when it is stationary at the Upper limit switch “0” (only if there is a box or other mechanical stop at this limit switch).
This procedure adjusts the limit of the traction force that the motor can exert on the awning in an attempt to release it, when it is stopped suddenly by an obstacle
or friction. At the same time, if the Upper limit switch “0” is the box or other mechanical stop, the system uses the same value set with this procedure, to reduce the
impact of the awning against the box and loosen the tension exerted by the motor on the canvas, when the awning is stationary at the Upper limit switch “0”.
• The following options are available:
MINIMUM sensitivity – this setting is only active when the awning is moving Up. The motor delivers a lot of force and will often be able to unjam the awning, even
when the load is varying due to friction or small obstacles.
ULTRA sensitivity(*) – this setting is active when the awning is moving Down.
ULTRA sensitivity(*) with brief inversion – this setting is active when the awning is moving Up or Down. If an obstacle is detected when the awning is moving
Down, the motor briefly inverts the movement to free it.
ULTRA sensitivity(*) with full inversion – this setting is active when the awning is moving Up or Down. If an obstacle is detected when the awning is moving Up,
the motor inverts the movement and stops the awning at the Lowest point “1”.
sensitivity DISABLED – this setting disables the safety system (factory setting).
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
= 5 sec
2
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Hold down both buttons... release them after 5
seconds;
count 2 movements.
4
continues
Select the de-
sired option and
program it as fol-
lows
(x ...)
5 OPTIONS:
1 press = sets MINIMUM sensitivity
2 presses = sets ULTRA sensitivity
3 presses = sets ULTRA sensitivity with short reverse
4 presses = sets ULTRA sensitivity, with reverse
5 presses = sets DISABLED sensitivity
Press and release the button the number of times indicated in the option you have chosen;
4
5
end
7
sec.
?
1 /
2 /
3 /
4 /
= 5 sec
3
After about 7 seconds, the motor performs a num-
ber of movements equal to the number of pulses
entered.
Hold down the button and release it after 5
seconds;
count 3 movements.
(*) IMPORTANT - After having programmed the option, or following the return of power after a blackout, 2 full manoeuvre cycles must be carried out straight
away (Up and Down = 1 cycle) to activate the function. During this movement, the motor maps the instantaneous load along its travel and automatically sets the
maximum sensitivity available with the awning in question.
AA