Installation Instructions

English – 18
–– GROUP “C” PROCEDURES ––
for motors configured for ONE-WAY communications
realizzabili esclusivamente con un trasmettitore Nice della serie “ERA P” o “ERA W”, dotato dei tasti s, n, t, PRG, ESC
GENERAL WARNINGS RELATING TO THE PROCEDURES
Before starting any programming, move the awning to an intermediate position, away from the Up and Down limit switch-
es.
If the programming transmitter controls multiple groups of screen motors, before sending a command requested by
the procedure, select the group to which the motor being programmed belongs.
When the motor is powered up, if it makes 2 movements this means that: at least one transmitter has been memorised
and no limit switch has been programmed; if, on the other hand, it makes 1 movement this means that: no transmitter
has been memorised.
When running a procedure, you can abort the procedure at any time by pressing ESC (on the back of the transmitter).
When the Up and Down limit switches are not programmed, the awning can only be commanded in hold-to-run mode -
i.e. you must hold the button down until the awning reaches the desired position. The movement stops when you release
the button in any position.
When the Up and Down limit switches have been programmed , the awning can be controlled by simply pressing and
releasing the buttons. Doing so starts the movement, which is stopped automatically by the system when the awning
reaches the programmed position.
All procedures require you to use a transmitter memorised in “Mode I” (e.g., memorised with procedure A.1 or with pro-
cedure C.2.1.A or C.2.1.B).
C.1 - Temporarily deactivating (and reactivating) motors you do not wish to program
NOTES AND WARNINGS
This procedure temporarily deactivates (for 5 minutes) only motors whose up and down limit switches have already been programmed.
C.1.1 - To temporarily deactivate motors you do not wish to program
1 2
end
ESC
= 5 sec
ESC
0
The system locks out only those motors whose limit
switches have already been programmed. It has no ef-
fect on motors which have not yet been programmed.
The deactivation is temporary and lasts for 5 min-
utes.
Hold down the but-
ton and
release it after 5 sec-
onds;
you will see a brief down
movement and a movement
which stops the awning at
the Up limit “0”.
For a period of 5 minutes, the locked out motors will not
respond to commands.
C.1.2 - To reactivate temporarily locked out motors
You can reactivate the motors in two ways:
option – A
1
end
option – B
1
end
After 5 minutes the
locked out motors are
automatically reactivat-
ed by the system.
During the 5 minute
period the locked out
motors can be reacti-
vated at any time by the
user.
ESC
= 10 sec
ESC
Wait for 5 minutes ... ... the system will then
move the awning to
the mid position.
During the 5 minutes, at
any time...
... hold down the
button and
release it after 10
seconds;
the system will then
move the awning to
the mid position.
C