Installation Instructions

English – 22
option – D
5
end
= 5 sec
5
Hold down both buttons... release them after 5
seconds;
count 5 movements.
C.4.2 - Procedure run with a transmitter which has not yet been memorised
NOTES AND WARNINGS
• In order to carry out the following procedures, a transmitter with a PRG button should be used.
C.4.2.A - Procedure run with a transmitter which has not yet been memorised and cables for the voltage free contacts
1 2 3 4
...
OFF
ON
Run procedure
C.4.1 in full.
Disconnect the electrical
power supply to the motor.
Connect the white and white-black
wires together.
Reconnect the electrical pow-
er supply to the motor once
again.
C.4.2.B - Procedure run with a transmitter that has not yet been memorised and the limit switch adjustment buttons on the motor head
1 2
...
= 5 sec
when the light starts
flashing, you have 1
minutes to complete
the procedure.
Run procedure
C.4.1 in full.
On the motor head: hold down both
buttons and
release them after 5 seconds; the red led starts flashing (it turns off when the procedure is
completed).
C.5 - Locking and unlocking the motor’s memory
NOTES AND WARNINGS
• Locking the motor’s memory stops any other (unscheduled or unauthorised) transmitters being memorised in it.
1 2 3
4
PRG
(x 1)
2
PRG
(x 1)
2
PRG
(x 1)
3
Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 2 movements. Press and release
the button (1 time);
count 3 movements.
4 5
...
= 5 sec
4
Select one of the following potions and execute it:
• option A – LOCK motor’s memory.
• option B – UNLOCK motor’s memory.
Hold down both buttons... release them after 5 sec-
onds;
count 4 movements.
option – A
5
end
option – B
5
end
= 5 sec
3
= 5 sec
5
Hold down the but-
ton and
release it after 5
seconds;
count 3 movements. Hold down the but-
ton and
release it after 5
seconds;
count 5 movements.
C