Installation Guide

What’s In The Box
One (1) CLR Five (5) Wire NutsOne (1) MC Connector
ATTENTION:
Turn power o before inspection, installation, or removal.
Suitable for use in dry, damp and wet indoor and outdoor locations. Use only on 120-277 VAC, 60Hz circuits.
NOTE:
Not all existing mounting frames will be compatible with the CLR. To ensure compatibility, a test installation should be conducted.
The CLR LED Retrot Kit is designed to be installed in a standard 6” or 8” CFL mounting frame.
CLR Select Commercial Recessed LED Downlight
INSTALLATION INSTRUCTIONS
Model(s):
CLR62SWRVS9WH
CLR82SWRVS9WH
CLR82HWRVS9WH
Tools Needed Frame Compatibility
This LED Recessed Kit requires very few tools for
installation. A screwdriver and a pair of wirecutters will
help to install the downlight to a JBox or housing.
CLR6: ” min - 7” max
CLR8: ” min - 9” max
Remove existing
lamp, trim and
socket cap.
1
Remove J-Box cover plate from existing lamp ballast. Do
not dispose. Disconnect all wires from ballast. Remove
the socket cap metal conduit (MC) cable from the J-Box.
2
CLR Kit Installation With Existing Frame
Make sure all power is turned o before beginning installation
WARNING:
Risk of electric shock. Disconnect power at fuse or circuit breaker before installing or servicing.
• To prevent early lamp failure, lamp should only be installed in operating environments between -20°C and + 4C (104°F and -F)
No user serviceable parts inside. To avoid electric shock do not disassemble product.
This product is not intended for use in emergency light xtures or exit signs.
This product is contains a chemical know to the state of California to cause cancer, birth defects and other reproductive harm.
Risk of re or electrical shock. Install this kit only in luminaires that have the construction features and dimensions shown in
the photographs and/or drawings.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.