Specification
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com February 18, 2020 1:39 PM CLR Select Page 1 of 3
CLR Select
6” and 8” Commercial Recessed LED Downlight
Type
Date
Catalog
Project
Product Description
Designed for both new construction and retrot applications, the CLR Select series can be installed
directly into drywall, a ceiling grid or an existing 6” or 8” mounting frame using spring loaded
retention tabs. The CCT and output selectable design allows for easy adjustment to 3000, 3500,
4000, or 5000K and standard or high output. With accessory trims in nickel, oil-rubbed bronze and
black, and oering a full range of dimming from 0-10 volts, the CLR Select is adaptable to most
any environment. The versatility of this light source is perfect for commercial applications, such as
educational, governmental, retail and grocery, oce or hospitality lighting.
Construction
• Cast aluminum ange and heat sink
• Plastic driver housing
• Output and CCT selection switches on back of housing
• Certied for direct contact with insulation
• Meets ASTM E283 airtight requirements
Optical System
• Precision engineered polystyrene diuser provides high uniformity, and reduced glare
• No visible diodes, hot-spots, or shadows
Electrical
• Wide range input voltage of 120 - 347 VAC
• Full-range dimming via 0-10VDC controls
• TM-21 Reported L70(9k) life >56,000 hours
• LM-79, LM-80 testing performed in accordance with IESNA standards
• Meets FCC 15 PartB: 2016 Class A requirements
Finish
• Matte white powder coat
• Color faceplate available (varies depending on size)
Mounting and Installation
• Adjustable, spring loaded retention tabs ensure secure xture retention on ceilings up to 1 ½” thick
• 2’ whip with 18” of FMC
• Easy installation into most 6” or 8” incandescent or uorescent frames
• Frame not needed for new construction installation
• Metal rough-in templates or frames available
• NON-IC Operating temperature of 0° to 104°F (-18°C to 40°C)
1
• IC Operating temperature of 0° to 77°F (-18° to 25°C)
1
• Suitable for wet locations
• For installations where power surge may be possible, NICOR recommends installing additional
surge protection at the xture or electrical distribution panel
Warranty
• 5-year limited system warranty standard
• Warranty does not cover product failure due to an overvoltage event (power surge)
A
D
H
Model Diameter Height Aperture Ø
CLR6 7.4in (188mm) 4.5in (114mm) 5.2in (132mm)
CLR8S 9.5in (240mm) 5.2in (132mm) 7.5in (191mm)
CLR8H 9.5in (240mm) 5.6in (143mm) 7.5in (191mm)
Representative image. Exact models vary.
1
1 - Except CLR8HO