Installation Guide

What’s In The Box
One (1) DLS4
Three (3) Wire Nuts
One (1) Screw-in Edison Base
One (1) Pair of Friction Clips
ATTENTION:
Turn power o before inspection, installation, or removal.
Suitable for use in wet locations. Use only on 120VAC, 60Hz circuits.
NOTE: This luminaire has been modied and can no longer operate the originally intended lamp. The
provided label must be applied to the retrotted luminaire where visible during re-lamping.
DLS Surface Mount LED Downlight
INSTALLATION INSTRUCTIONS
Model(s):
DLS4-3006-120-#K-WH
Tools Needed
This LED Surface Mount LED Downlight requires very few
tools for installation. A screwdriver and a pair of wirecutters will
help to install the downlight to a JBox or housing.
Cut o xture connector and strip back wires minimum 3/8”.
1
Align screws (2) to JBox, mount DLS to Jbox by tightening screws.
3a
Make sure building wires are accessible from the JBox and splice
the xture wires to the building wires with wire nuts (included):
black to live (black), white to neutral (white), and green to ground.
2
Carefully tuck the wires into the J-Box.
2a
Standard 4” J-Box Installation
Make sure all power is turned o before beginning installation
Twist o DLS lens by twisting lens
counterclockwise.
3
Twist DLS lens back on by
twisting lens clockwise.
Power on the xtures to enjoy your
new surface mount LED downlight.
4
5
WARNING:
•Risk of electric shock. Disconnect power at fuse or circuit breaker before installing or servicing.
•To prevent early lamp failure, lamp should only be installed in operating environments between -20°C and + 40°C (104°F and -4°F)
•No user serviceable parts inside. To avoid electric shock do not disassemble product.
•This product is not intended for use in emergency light xtures or exit signs.