Ordering Information
Series Version Voltage CCT Housing Color Photocell Testing Cold Weather Emergency
EOT 1 MV (120-277V) 2K (2700K) BZ (Bronze) P (Photocell) _ (Manual) _ (Standard) __ (Emergency)
5K (5000K) WH (White) S (Self-Diagnostic,
EM only)
C (Cold Weather) AC (Non-EM)
BK (Black)
SV (Silver)
EOT1MV2K
Input Voltage (VAC)
120/277
System Level Power (W)
13
Delivered Lumens - Standard Operation (Lm)
1074
System Ecacy (Lm/W)
80
Correlated Color Temp (K)
2756
Color Rendering Index (CRI)
83
Delivered Lumens - Emergency Operation (Lm)
277
Emergency Operation
90 min
Example: EOT1MV2KBZPS
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 305 28.4%
0-40 495 46.1%
0-60 871 81.1%
0-90 1074 100%
90-180 0.00 0%
0-180 1074 100%
Intensity Summary
(Candle Power)
Angle Mean CP
0
318
5
322
15
284
25
203
35
122
45
65
55
9
65
7
75
4
85
2
90
2
CCT Data Multiplier
EOT1MV5K 1.078
Photometric Data
517
387
258
129
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.