Specification

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com August 1, 2017 4:34 PM
Photometric Data
3500K LSC 2’
Input Voltage (VAC)
120-277
System Level Power (W)
19.37
Delivered Lumens (Lm)
2502
System Ecacy (Lm/W)
129.17
Correlated Color Temp (K)
3446
Color Rendering Index (CRI)
82
Beam Angle
118°
Spacing Criteria (0°)
1.18
Spacing Criteria (90°)
1.22
3500K LSC 4S
Input Voltage (VAC)
120-277
System Level Power (W)
21.95
Delivered Lumens (Lm)
2828
System Ecacy (Lm/W)
128.83
Correlated Color Temp (K)
3463
Color Rendering Index (CRI)
82
Beam Angle
118°
Spacing Criteria (0°)
1.18
Spacing Criteria (90°)
1.22
3500K LSC 4H
Input Voltage (VAC)
120-277
System Level Power (W)
45.81
Delivered Lumens (Lm)
5853
System Ecacy (Lm/W)
127.76
Correlated Color Temp (K)
3474
Color Rendering Index (CRI)
82
Beam Angle
118°
Spacing Criteria (0°)
1.18
Spacing Criteria (90°)
1.22
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 613 25%
0-40 991 40%
0-60 1731 69%
0-90 2319 93%
90-180 183 7%
0-180 2502 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 693 25%
0-40 1120 40%
0-60 1957 69%
0-90 2622 93%
90-180 206 7%
0-180 2828 100%
Zonal Lumen Summary
Zone Lumens % of Luminaire
0-30 1434 25%
0-40 2318 40%
0-60 4050 69%
0-90 5426 93%
90-180 427 7%
0-180 5853 100%
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
8 12.74 13.31
10 8.15 16.64
12 5.66 19.97
14 4.16 23.30
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
8 14.40 13.31
10 9.22 16.64
12 6.40 19.97
14 4.70 23.30
Cone of Light Tabulation
Mounted height
(Feet)
Footcandles
Beam Center
Diameter
(Feet)
8 29.80 13.31
10 19.07 16.64
12 13.25 19.97
14 9.73 23.30
CCT Data Multiplier
LSC-10-2S-UNV-40 1.018
LSC-10-2S-UNV-40 1.035
CCT Data Multiplier
LSC-10-4S-UNV-40
1.018
LSC-10-4S-UNV-50
1.035
CCT Data Multiplier
LSC-10-4H-UNV-40
1.018
LSC-10-4H-UNV-50
1.035
Fixture tested per LM-79-08. Photometric data is of the performance
of a representative xture. Results may vary in the eld.
Fixture tested per LM-79-08. Photometric data is of the performance
of a representative xture. Results may vary in the eld.
Fixture tested per LM-79-08. Photometric data is of the performance
of a representative xture. Results may vary in the eld.
Intensity Summary
(Candela Power)
Angle 0° (Along) 90° (Across)
0 815 815
15 767 764
30 639 662
45 480 657
60 288 391
75 112 255
90 0 153
105 0 85
120 0 51
135 0 34
150 0 17
165 0 0
180 0 0
Intensity Summary
(Candela Power)
Angle 0° (Along) 90° (Across)
0 922 922
15 867 864
30 723 749
45 542 595
60 324 442
75 127 288
90 0 173
105 0 96
120 0 58
135 0 38
150 0 19
165 0 0
180 0 0
Intensity Summary
(Candela Power)
Angle 0° (Along) 90° (Across)
0 1907 1907
15 1795 1788
30 1496 1550
45 1122 1232
60 673 914
75 262 596
90 0 358
105 0 199
120 0 119
135 0 79
150 0 40
165 0 0
180 0 0
477
230
204
954
461
408
1430
691
611
1907
922
815