Installation Guide

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393 www.nicorlighting.com October 8, 2021 9:22 AM PRCP2 Rev - Page 3 of 4
Prime Chime Plus - INSTALLATION INSTRUCTIONS Model: PRCP2
Installing multiple Prime Chime Plus (2 max, 70’ spacing to rst unit. 200’ total length)
Carefully unpack xture and faceplate.
1
Connect line voltage wiring (120VAC, 18ga or greater)
at each unit per the diagram.
2
Connect low voltage bell wires (18ga or 22ga) into the
rst unit into ports 1(+) and 2(-).
3
Junction
Box
Black (Line)
Black (Line)
White (Neutral)
White (Neutral)
120V/60Hz only
Run bell wiring from ports 3(+) and 4(-) of the rst unit
into ports 1(+) and 2(-) of the next unit, max 1 additional
unit. Leave ports 3 and 4 of the last unit open.
Note: If continuos ringing is present, switch the input to the
second chime, port 3 into port 2, port 4 into port 1.
4a
4b
See below for basic diagram of multiple chime wiring.
5 6
Attach faceplate by pressing onto chime.
Install chime into junction box using four (4) included
screws.