7. Environmental condition
7.1 Operating temperature/humidity
0 ~ +50 degrees C, 10% ~ 85% RH
No abnormality is found in the card.
In 0 ~ +5 degrees C range, (except "warped capability")
Wet bulb temperature : Less than 30 degrees C.
7.2 Storage temperature/humidity
-5 ~ +50 degrees C, 8% ~ 95% RH
Conditions:
Storing SCT for 12 hours at the normal conditions (refer to 9.1 Note1) without any operation
after keeping it at the above storage temperature and humidity for 96 hours without operation,
no functional error is found.
7.3 Vibration durability
Operating:
Range of frequency : 5 ~ 50Hz
Acceleration : 2 m/s
2
(0.2G)
Sweep method : Logarithmic sweep, 2 min/1 octave
X.Y.Z. each direction 20 minutes.
No functional error is found after vibration test.
Non-Operating:
Range of frequency : 5 ~ 50Hz
Acceleration : 2.5 m/s
2
(0.25G)
Sweep method : Logarithmic sweep, 2 min/1 octave
X.Y.Z. each direction 20 minutes.
No functional error is found after vibration test.
7.4 Shock durability (within package)
294 m/s
2
(30G), 11 msec
X.Y.Z. each direction one time.
No functional error is found after shock durability test.
7.5 EMC Capability
FCC Part 15 (The attestation is still undecided.)
7.6 Mounting posture
Horizontal +/- 3 degrees