User's Manual

Spectra Precision Focus 4 Total Station User Guide 133
Specifications A
The external device connector is a Hirose HR 10A-7R-6S female connector. The
pinouts for connecting the Focus 4 to an external device connector are shown below:
C
CAUTION – Only use the pin connections shown above. Using other connections will
damage the instrument.
C
CAUTION – The Focus 4 total station has different pin assignments from other Spectra
Precision total stations.
To connect to an external power source, supply power to Pin 4 (power terminal) and
Pin 5 (ground terminal) on the instrument. The instrument will use the external power
source even if the internal battery packs is attached.
C
CAUTION – Make sure that the power supplied is within the rated input range (4.5 V to
5.2 V, 1 A maximum). Power supplied outside this range will damage the instrument.
To communicate with an external device, connect the RS-232C signal from the
external device to Pin 1 (input terminal) and to Pin 2 (output terminal) on the Focus 4.
Cap the data output/external power input connector securely when the Focus 4 is not
in use. The instrument is not watertight if the cap is detached or not attached securely,
or when the data output/external power input connector is in use.
The Focus 4 can be damaged by static electricity from the human body discharged
through the data output/external power input connector. Before handling the
instrument, touch any other conductive material once to remove static electricity.
Pin Signal Description
1 RxD Receive data (Input)
2 TxD Send data (Output)
3 NC No connection
4VPower
5 GND Ground
6 NC No connection
HRS
16