User's Manual

Total Station Nivo Series Instruction Manual 121
Menu Key 5
A confirmation screen appears.
4. Do one of the following:
To accept the changes and return to the data
view screen, press [ENT] or the Yes softkey.
To go back to the edit screen, press [ESC] or
the No softkey.
Editing station records
Note – The system will not recalculate measurements if you change the station record.
All coordinate and raw data observed from an edited station record must be
recalculated in your postprocessing software.
In the RAW screen, use
[^] or [v] to highlight the station
record that you want to edit. Then press the Edit
softkey.
You can edit any field in the ST record, but the
instrument does not recalculate any measurements
from this station.
Press [ENT] in the AZ field to confirm the change.
If you change the ST or HI values, the coordinates of observation points are not recalculated. A comment record
is stored to record the change. The following example shows a comment record for a changed HI value:
CO,HI changed at ST:9012 Old HI= 1.345m
If you change the BS or AZ values, raw records are not recalculated. A comment record is stored to record the
change.