User's Manual

Total Station Nivo Series Instruction Manual 173
Error Messages 10
Recording Data
DATA FULL
100.18
The data storage is full.
Press any key to return to the Basic Measurement Screen (BMS). Then:
DUPLICATE PT
100.19
The input PT you are trying to record already exists in the current job. An existing
coordinate record cannot be overwritten by measured data.
Press any key to return to the point input screen. Change PT.
Duplicate PT
100.20
The input PT you are trying to record already exists in the current job as an SS, SO, or
CP record. An existing SS, SO, or CP record can be overwritten by measured data.
No Open Job
100.21
No job is open.
NO Stn Setup
100.22
There is no station record in the current job, or a station setup or BS check has not
been done since the program was rebooted.
To ... Go to ...
delete unnecessary data
MENU > Data
delete jobs
MENU > Job
To ... Press ...
return to the PT input screen [ESC] or the Abrt softkey
record RAW data and update XYZ data the XYZ softkey
record RAW data only the RAW softkey
To ... Press ...
open the job list, if there are existing jobs [1] or select Select job
create a new job [2] or select Create job
return to the previous screen
[ESC]
To ... Press ...
continue recording [1] or select Continue. If there is already an ST record in the
job, the message
CO, Use current orientation
appears.
go to the Stn Setup menu [2] or select STN Setup
return to the previous screen
[ESC]