User's Manual

Trimble TS635 Construction Total Station User Guide 115
Specifications A
External device connector
This connector can be used to connect to an external power source or to
communicate with an external device.
Before using the external device connector, make sure that the external device meets
the specifications below.
C
CAUTION – Except when connected as shown in the System diagram, page 14, use of the
Hirose HR10A-7P-6P or HR10-7P-6P is at your own risk.
C
CAUTION – Use only the male connectors specified above. Using other connectors will
damage the instrument.
The external device connector is a Hirose HR 10A-7R-6S female connector. The
pinouts for connecting the instrument to an external device connector are shown
below:
C
CAUTION – Only use the pin connections shown above. Using other connections will
damage the instrument.
C
CAUTION – The TS635 total station has different pin assignments from other Construction
total stations.
To connect to an external power source, supply power to Pin 4 (power terminal) and
Pin 5 (ground terminal) on the instrument. The instrument will use the external power
source even if the internal battery packs is attached.
C
CAUTION – Make sure that the power supplied is within the rated input range (4.5 V to
5.2 V, 1 A maximum). Power supplied outside this range will damage the instrument.
Input voltage 4.5 V DC to 5.2 V DC
System RS-232C
Signal level ±9 V standard
Maximum baud rate 38400 bps asynchronous
Compatible male connector Hirose HR10A-7P-6P or HR10-7P-6P
Pin Signal Description
1 RxD Receive data (Input)
2 TxD Send data (Output)
3 NC No connection
4VPower
5 GND Ground
6 NC No connection
HRS
16
25
34