User's Manual

Total Station Nivo Series Instruction Manual 33
Getting Started 3
Quick code measurement mode
1. To activate Quick code measurement mode,
press
[MODE] in the BMS.
The PT field shows the default point name.
2. Press any numeric key (
[0] through [9]) to start
measuring and recording points.
A list of the numeric keys and their assigned
feature codes appears on the right side of the
screen.
For example, when you press
[6], the code
assigned to 6 is selected, and the instrument
starts a measurement.
3. If you have set the record mode to Confirm (see
Measurement settings, page 48), the Record PT
screen appears after each measurement.
Do one of the following:
To record the point, press [ENT].
To return to the BMS, press [ESC].
4. To return to the BMS from the Qcode screen, press
[MODE] or [ESC].
[COD] key
In the BMS, press [COD] to change the default feature code that will appear in the CD
field when you record a point.
Setting the default code
When you press
[COD] in the BMS, a window for
entering the feature code appears.
You can use the
List and Stack softkeys to enter the
code.
To assign a new feature code to a numeric key, press [^] or [v] to highlight the code that you want to change. Then
press the Edit softkey.
You can use the DSP softkey to change the values shown in the measurement box, in the same way as you use
the [DSP] key in the Basic Measurement Screen (BMS).