User's Manual

4 Applications
84 Total Station Nivo Series Instruction Manual
You can enter any combination of taped offset
distances to specify the point.
4. To go to the recording PT screen, press
[ENT] in
the last field.
The calculated coordinates are shown.
5. Enter a PT (and CD) value.
6. Press
[ENT] to record the point.
Raw data is also recalculated, based on the taped
offset value.
Measuring angle offsets
1. To enter the angle offset function, press [2] or
select
Angle in the Offset menu.
If you have not taken a distance measurement
before entering this function, a temporary
measurement screen appears.
2. Sight the target and press
[MSR1] or [MSR2].
3. To take the angle offset, rotate the alidade and
telescope. The measured distance (HD) remains
unchanged.
4. To record the offset point, press
[ENT] or the OK
softkey.
The XYZ data is also recalculated, based on the new angle.
You can record an angle offset in the Basic Measurement Screen (BMS). After taking a distance measurement,
rotate the alidade and/or telescope. Then press [ENT] to record the measured distance with the updated angle
value. If you use this method, the dimension of the angle offset is not stored as a CO record. To store the CO
record, use the O/S function.