User's Manual

Trimble TS635 Construction Total Station User Guide 45
Getting Started 3
Regional configuration
To provide easier configuration for common regional settings, you can quickly
configure the TS635 Construction Total Station to a pre-set combination of default
regional settings. The Regional Configuration screen appears only after the language
configuration is complete and the instrument has rebooted.
1. Follow the steps in the language section on page 95.
Once the instrument reboots, the Regional
Configuration screen appears.
2. Press
[^] or [v] to highlight the required regional
settings and then press
[ENT].
3. If you do not want to change the current settings,
press
[ESC] and quit. The instrument will continue
to use the last settings that were configured.
The settings affected by the Regional Configuration screen are:
Category Setting Europe International United States
Angle VA zero Zenith Zenith Zenith
Resolution 5" 5" 5"
Distance Scale 1.000000 1.000000 1.000000
T-P Corr. On On On
Sea Level Off Off Off
C&R corr. 0.132 0.132 0.132
Coordinates Order ENZ ENZ NEZ
Label ENZ ENZ NEZ
Power Save Main Unit Off Off Off
EDM Unit Off Off Off
Sleep 5 minutes 5 minutes 5 minutes
Communication Ext. Comm Nikon Nikon Nikon
Baud 4800 4800 4800
Length 8 8 8
Parity None None None
Stop bit 1 1 1
Units Angle GON DEG DEG
Distance meters meters US-ft
Temp °C °C °F
Press mm Hg mm Hg In Hg
Rec Rec Data ON ON ON
CD Field ON ON ON
Add Const 1000 1000 1000
Others XYZ disp Fast Fast Fast
2nd Unit None None None
CD Input <ABC> <ABC> <ABC>