User's Manual

4 Applications
84 Spectra Precision Focus 4 Total Station User Guide
To start searching for matching points, press [ENT] in the
To field. The counter shows the number of matching
points found.
When the search is complete, you are returned to the
Input PT screen.
Select the
Calc softkey to calculate the area and
perimeter, or enter point names in the PT field.
Press
[ESC] to return to the Input PT screen where the
preceding point name appears.
Note – If you search for a point when a control job is specified, and the system cannot find
the point in the current job, the control job is also searched. If the point is found in the
control job, it is copied to the current job as a UP record. See also Setting the control job,
page 95.
Down+Out
Choose this option from the Cogo menu to calculate coordinates from Down and Out.
Press
[4] or select Down & Out in the Cogo menu.
Enter the base point (P1).
Specify the azimuth bearing. To do this, enter a value in
the HA or P2 field. P2 is a second point on the line.
Enter the horizontal distance along the baseline (Dwn), the horizontal distance
perpendicular to the line (Out), and the vertical distance (dVD).
HA
P2
P1